beautypg.com

Technical data – KROHNE OPTISONIC 6300 Quickstart EN User Manual

Page 48

background image

4

TECHNICAL DATA

48

OPTISONIC 6300

www.krohne.com

07/2009 - 7.30959.24.00 - QS OPTISONIC 6300 R04 en

Inputs and outputs

General

All in- and outputs are galvanically isolated from each other and from

all other circuits

Description of used abbreviations U

ext

= external voltage; R

L

= load + resistance; U

o

= terminal voltage;

I

nom

= nominal current

Current output

Current output

Current output

Current output

Output data

Measurement of volume and mass (at constant density), HART

®

communication

Settings

Without HART

Without HART

Without HART

Without HART

®

Q = 0%: 0…20 mA; Q = 100%: 10…21.5 mA

Error identification: 0…22 mA

With HART

With HART

With HART

With HART

®

Q = 0%: 4…20 mA; Q = 100%: 10…21.5 mA

Error identification: 3.5…22 mA

Operating data

Basic I/Os

Basic I/Os

Basic I/Os

Basic I/Os

Modular I/Os

Modular I/Os

Modular I/Os

Modular I/Os

Ex-i

Ex-i

Ex-i

Ex-i

Active

U

int,nom

= 24 VDC

I ≤ 22 mA

R

L

≤ 1 kΩ

U

int,nom

= 20 VDC

I ≤ 22 mA

R

L

≤ 450 Ω

U

0

= 21 V

I

0

= 90 mA

P

0

= 0.5W

C

0

= 90 nF /

L

0

= 2 mH

C

0

= 110 nF /

L

0

= 0.5 mH

Passive

U

ext

≤ 32 VDC

I ≤ 22 mA

U

0

≥ 1.8 V at I = 22 mA

U

ext

≤ 32 VDC

I ≤ 22 mA

U

0

≥ 4 V

R

L

≤(U

ext

- U

o

) / I

max

U

I

= 30 V

I

I

= 100 mA

P

I

= 1 W

C

I

= 10 nF

L

I

~ 0 mH

HART

HART

HART

HART

®

Description

HART

®

protocol at active and passive current output

HART

®

version: V5

Universal HART

®

parameter fully integrated

Load

≥ 250 Ω

Please observe maximum value for current output

Multidrop

Yes, current output = 4 mA

Multidrop addresses programmable in menu 1...15

Device drivers

FDT/DTM

.book Page 48 Wednesday, August 19, 2009 8:37 AM