background image

4

TECHNICAL DATA

46

OPTISONIC 6300

www.krohne.com

07/2009 - 7.30959.24.00 - QS OPTISONIC 6300 R04 en

Display and user interface

Display and user interface

Display and user interface

Display and user interface

Graphic display

LC display, backlit white

Size: 128x64 pixels, corresponds to 59x31 mm = 2.32"x1.22"

Display turnable in 90° steps

The readability of the display could be reduced at ambient

temperatures below -25°C / -13°F.

Operator input elements

4 optical keys for operator control of the signal converter without

opening the housing.

Option: Infrared interface (GDC)

Remote control

PACTware

®

including Device Type Manager (DTM)

All DTM's and drivers are available at the internet homepage of the

manufacturer.

Display functions

Display functions

Display functions

Display functions

Menu

Programming of parameters at 2 measured value pages, 1 status

page, 1 graphic page (measured values and descriptions adjustable

as required)

Language of display texts

English, French, German

Units

Metric, British and US units selectable from list / free unit

Measuring accuracy

Reference conditions

Medium: water

Temperature: 20°C / 68°F

Straight inlet section: 10 DN

Maximum measuring error

±

1% of the measured value

for DN≥50 mm / 2" and v > 0.5 m/s / 1.5 ft/s

±

3% of the measured value

for DN<50 mm / 2" and v > 0.5 m/s / 1.5 ft/s

Repeatability

<±0.2%

Operating conditions

Temperature

Temperature

Temperature

Temperature

Process temperature

Standard version: -40...+120°C / -40...+248°F

XT version: -40...+200°C / -40...+392°F

Ambient temperature

Sensor: -40...+70°C / -40...+158°F

Signal converter: -40…+60°C / -40…+140°F

(ambient temperature 55°C / 131°F and higher: protect electronics

against self-heating, because an increase in the electronics

temperature in 10°C / 50°F steps leads to a corresponding reduction

of the electronics' service life by a factor of two).

Storage temperature

-50…+70°C / -58…+158°F

Pipe specifications

Pipe specifications

Pipe specifications

Pipe specifications

Material

Metal, plastic, ceramic, asbestos cement, internal / external coated

pipes (coatings and liners fully bonded to pipe wall)

Pipewall thickness

< 200 mm / 7.87"

Liner thickness

< 20 mm / 0.79"

.book Page 46 Wednesday, August 19, 2009 8:37 AM