TECHNICAL DATA

4

47

OPTISONIC 6300

www.krohne.com

07/2009 - 7.30959.24.00 - QS OPTISONIC 6300 R04 en

Media properties

Media properties

Media properties

Media properties

Physical condition

Liquids

Viscosity

< 100 cSt (general guideline)

For detailed information please contact your local representative.

Permissible gas content (volume) ≤ 2%

Permissible solid content

(volume)

≤ 5%

Recommended flow velocity

0.5...20 m/s

Other conditions

Other conditions

Other conditions

Other conditions

Protection category acc. to

IEC 529 / EN 60529

W (Wall) version signal converter:

IP 65 (acc. to NEMA 4/4x)

F (Field) version signal converter:

IP 66/67 (acc. to NEMA 4x/6)

All sensors:

IP 67 (acc. to NEMA 6)

Vibration resistance

IEC 68-2-64

Shock resistance

IEC 60068-2-27

Installation condititions

Measurement configuration

Single path, single pipe or dual path / dual pipe

Inlet run

≥ 10 DN straight length

Outlet run

≥ 5 DN straight length

Dimensions and weights

See chapter "Dimensions and weights"

Materials

Sensor

Standard

Standard

Standard

Standard

Anodised aluminum

Option stainless steel / eXtended Temperature (small / medium

Option stainless steel / eXtended Temperature (small / medium

Option stainless steel / eXtended Temperature (small / medium

Option stainless steel / eXtended Temperature (small / medium

version)

version)

version)

version)

Rail construction: 1.4404 (AISI 316L)

Cable connection:1.4404, PSU with FKM O-ring

Converter

Standard

Standard

Standard

Standard

F version: die-cast aluminum, polyurethane coated

W version: polyamide-polycarbonate

Option

Option

Option

Option

F version: stainless steel 316 L (1.4408)

Electrical connections

Voltage

Standard: 100…230 VAC (-15% / +10%), 50/60 Hz

Option: 24 VAC/DC (AC: -15% / +10%; DC: -25% / +30%)

Power consumption

AC: 22 VA

DC: 12 W

Signal cable

double shielded, 2 internal triax, available lengths:

5 m / 15 ft (standard), maximum length 30 m / 90 ft

Cable entries

Standard: M20 x 1.5

Option: ½" NPT, PF ½

.book Page 47 Wednesday, August 19, 2009 8:37 AM