beautypg.com

Electrical connections – KROHNE OPTISONIC 6300 Quickstart EN User Manual

Page 24

background image

2

ELECTRICAL CONNECTIONS

24

OPTISONIC 6300

www.krohne.com

07/2009 - 7.30959.24.00 - QS OPTISONIC 6300 R04 en

2.3.3 Signal cable to converter

2.3.4 Laying electrical cables correctly

1 Lay the cable in a loop just before the housing.
2 Tighten the screw connection of the cable entry securely.
3 Never mount the housing with the cable entries facing upwards.
4 Seal cable entries that are not needed with a plug.

CAUTION!
Connect coax cables and follow indications up/down (1U 1D; 2U 2D; 3U 3D).

Figure 2-8: Connect signal cable (field version)

Figure 2-9: Connect signal cable (wall-mounted version)

Figure 2-10: Protect housing from dust and water

.book Page 24 Wednesday, August 19, 2009 8:37 AM