B.31 [SOURce:]MEASure[:SCALar]:POWer[:DC]? QUERY
MEAS:POW?
Syntax:
Short Form: [SOUR:]MEAS[:SCAL]:POW[:DC]?
Long Form: [SOURce:]MEASure[:SCALar]:POWer[:DC]?
Returns: Measured values in the form 0.000 Kilowatts
Description: Measures power. Measured returned as XXX Kilowatts, where XXX is format determined by
POWer:RANGe command (see PAR. B.61)
B.32 [SOURce:]MEASure[:SCALar]:VOLTage[:DC]? QUERY
MEAS:VOLT?
Syntax:
Short Form: [SOUR:]MEAS[:SCAL]:VOLT[:DC]?
Long Form: [SOURce:]MEASure[:SCALar]:VOLTage[:DC]?
Returns: Measured values in the form XXX Volts
Description: Measures voltage. Measured returned as XXX Volts, where XXX is format determined by VOLT-
age:RANGe command (see PAR. B.81)
B.33 [SOURce:]CONDuctance[:LEVel][:IMMediate][:AMPlitude] COMMAND
COND
Syntax:
Short Form:[SOUR:]CONDuctance[:LEVel][:IMMediate][:AMPlitude]
Long Form: [SOURce:]CONDuctance[:LEVel][:IMMediate][:AMPlitude]
Where
Description: Establishes conductance setpoint. Conductance setpoint is stored in non-volatile memory; value is
restored upon power-up.
B.34 [SOURce:]CONDuctance[:LEVel][:IMMediate][:AMPlitude]? QUERY
COND?
Syntax:
Short Form:[SOUR:]CONDuctance[:LEVel][:IMMediate][:AMPlitude]?
Long Form: [SOURce:]CONDuctance[:LEVel][:IMMediate][:AMPlitude]?
Returns
Description: Indicates conductance setpoint.
B.35 [SOURce:]CONDuctance:MODE COMMAND
COND:MODE
Syntax:
Short Form: [SOUR:]COND:MOD
Long Form: [SOURce:]CONDuctance:MODE
Description: Selects conductance mode.
B.36 [SOURce:]CONDuctance:MODE? QUERY
COND:MODE?
Syntax:
Short Form: [SOUR:]COND:MOD?
Long Form: [SOURce:]CONDuctance:MODE?
Returns:
Description: Returns the present mode: CURRent, POWer, VOLTage, RESistance, CONDuctance, OFF
B.37 [SOURce:]CONDuctance:RANGe COMMAND
COND:RANG
Syntax:
Short Form: [SOUR:]COND:RANG
Long Form: [SOURce:]CONDuctance:RANGe
Where
Description: Controls the placement of the decimal point during remote interface readback of conductance,
and on the front panel KW display when showing conductance.
Display Ranges: 0 - Auto, 1 - 0.000, 2 - 00.00, 3 - 000.0, 4 - 0000.
B.38 [SOURce:]CONDuctance:RANGe? QUERY
COND:RANG?
Syntax:
Short Form: [SOUR:]COND:RANG?
Long Form: [SOURce:]CONDuctance:RANGe?
Returns
Description: Indicates the placement of the decimal point during remote interface readback of conductance,
and on the front panel KW display when showing conductance.
Display Ranges: 0 - Auto, 1 - 0.000, 2 - 00.00, 3 - 000.0, 4 - 0000.