B.86 STATus:CHANnel:CONDition? QUERY
STAT:CHAN:COND?
Syntax:
Short Form: STAT:CHAN:COND?
Long Form: STATus:CHANnel:CONDition?
Returns: <16 bits> = the value of the Channel condition register.
Description: Returns the value of the Channel Condition Register. Each PFM within a chassis has three Chan-
nel registers associated with it. The Condition register reflects the instantaneous state of that PFM.
Bits in the Event register are set whenever the associated condition occurs, and are cleared only upon
an explicit command, thus latching any conditions that occur. See Table B-2 for bit assignments.
B.87 STATus:CHANnel:ENABle COMMAND
STAT:CHAN:ENAB
Syntax:
Short Form: STAT:CHAN:ENAB
Long Form: STATus:CHANnel:ENABle
Where
Description: Sets the Channel Enable Register to determine which bits are allowed to set the channel event
register. Each PFM within a chassis has three Channel registers associated with it. The Enable regis-
ter selects which of the latched bits in the Event register can propagate to higher-level indicators. See
Table B-2 for bit assignments.
B.88 STATus:CHANnel:ENABle? QUERY
STAT:CHAN:ENAB?
Syntax:
Short Form: STAT:CHAN:ENAB?
Long Form: STATus:CHANnel:ENABle?
Returns: <16 bits> = the value of the Channel enable register.
Description: Returns the value of the Channel Enable Register. See Table B-2 for bit assignments.
B.89 STATus:CSUMmary[:EVENt]? QUERY
STAT:CSUM?
Syntax:
Short Form: STAT:CSUM[:EVEN]?
Long Form: STATus:CSUMmary[:EVENt]?
Returns: <16 bits> = the value of the Channel summary register.
Description: Returns the value of the Channel Summary Register. The Channel Summary Group contains an
Event and Enable register which sums the
TABLE B-2. CHANNEL STATUS CONDITION,
ENABLE, AND EVENT REGISTER BITS
CONDITION
NU
PS
OV
LRV
UNR RRV
EPU
NU
OT
OP
NU OC VF
BIT
14-15
13
12
11
10
9
8
5 - 7
4
3
2
1
0
VALUE
16384-
32768
8192 4096 2048 1024
512
256
32-128
16
8
4
2
1
EPU EXTENDED PWR UNAVAILABLE
LRV LOCAL REVERSE VOLTAGE
NU -
NOT USED
OC
OVERCURRENT
OP
OVERPOWER
OT
OVERTEMPERATURE
OV
OVERVOLTAGE
PS
PROTECTION SHUTDOWN
RRV REMOTE REVERSE VOLTAGE
UNR UNREGULATED
VF
VOLTAGE FAULT
TABLE B-3. CHANNEL SUMMARY ENABLE
AND EVENT REGISTER BITS
CONDITION
NU
SL14
SL13 SL12 SL11 SL10 SL9 SL8 SL7 SL6 SL5 SL4 SL3 SL2 SL1 MSTR
BIT
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
VALUE
32768 16384
8192 4096 2048 1024
512
256 128
64
32
16
8
4
2
1
MSTR MASTER
NU
NOT USED
SL1
SLAVE 1
through
SL14 SLAVE 14