B.32 [SOURce:]MEASure[:SCALar]:CURRent[:DC]? QUERY

MEAS:CURR?

Syntax:

Short Form: [SOUR:]MEAS[:SCAL]:CURR[:DC]?
Long Form: [SOURce:]MEASure[:SCALar]:CURRent[:DC]?
Returns: Measured values.

Description: Measures current. Measured returned as XXX Amps, where XXX is format determined by CUR-

Rent:RANGe command (see PAR. B.49)

B.33 [SOURce:]MEASure[:SCALar]:POWer[:DC]? QUERY

MEAS:POW?

Syntax:

Short Form: [SOUR:]MEAS[:SCAL]:POW[:DC]?
Long Form: [SOURce:]MEASure[:SCALar]:POWer[:DC]?
Returns: Measured values in the form 0.000 Kilowatts

Description: Measures power. Measured returned as XXX Kilowatts, where XXX is format determined by

POWer:RANGe command (see PAR. B.63)

B.34 [SOURce:]MEASure[:SCALar]:VOLTage[:DC]? QUERY

MEAS:VOLT?

Syntax:

Short Form: [SOUR:]MEAS[:SCAL]:VOLT[:DC]?
Long Form: [SOURce:]MEASure[:SCALar]:VOLTage[:DC]?
Returns: Measured values in the form XXX Volts

Description: Measures voltage. Measured returned as XXX Volts, where XXX is format determined by VOLT-

age:RANGe command (see PAR. B.83)

B.35 [SOURce:]CONDuctance[:LEVel][:IMMediate][:AMPlitude] COMMAND

COND

Syntax:

Short Form:[SOUR:]CONDuctance[:LEVel][:IMMediate][:AMPlitude]
Long Form: [SOURce:]CONDuctance[:LEVel][:IMMediate][:AMPlitude]
Where = conductance setpoint in Siemens

Description: Establishes conductance setpoint. Conductance setpoint is stored in non-volatile memory; value is

restored upon power-up.

B.36 [SOURce:]CONDuctance[:LEVel][:IMMediate][:AMPlitude]? QUERY

COND?

Syntax:

Short Form:[SOUR:]CONDuctance[:LEVel][:IMMediate][:AMPlitude]?
Long Form: [SOURce:]CONDuctance[:LEVel][:IMMediate][:AMPlitude]?
Returns = conductance setpoint in Siemens

Description: Indicates conductance setpoint.

B.37 [SOURce:]CONDuctance:MODE COMMAND

COND:MODE

Syntax:

Short Form: [SOUR:]COND:MOD

Long Form: [SOURce:]CONDuctance:MODE

Description: Selects conductance mode.

B.38 [SOURce:]CONDuctance:MODE? QUERY

COND:MODE?

Syntax:

Short Form: [SOUR:]COND:MOD?

Long Form: [SOURce:]CONDuctance:MODE?

Returns: = CURR, POW, VOLT, RES, COND, OFF

Description: Returns the present mode: CURRent, POWer, VOLTage, RESistance, CONDuctance, OFF

B.39 [SOURce:]CONDuctance:RANGe COMMAND

COND:RANG

Syntax:

Short Form: [SOUR:]COND:RANG

Long Form: [SOURce:]CONDuctance:RANGe

Where = 0, 1, 2, 3, or 4

Description: Controls the placement of the decimal point during remote interface readback of conductance,

and on the front panel KW display when showing conductance.
Display Ranges: 0 - Auto, 1 - 0.000, 2 - 00.00, 3 - 000.0, 4 - 0000.