beautypg.com

B.48 [source:]current:protection:state? query, B.49 [source:]current:range command, B.50 [source:]current:range? query – KEPCO EL Series Electronic Load Operator Manual P/N 243-1295 Firmware Version 3.12 (Unit Rev 2) User Manual

Page 68: B.51 [source:]function command, B.52 [source:]function query, B.53 [source:]mode command, B.54 [source:]mode? query, B.48, Source, B.49

background image

B-8

SERIES EL 070110

B.48 [SOURce:]CURRent:PROTection:STATe? QUERY

CURR:PROT:STAT?

Syntax:

Short Form: [SOUR:]CURR:PROT:STAT?
Long Form: [SOURce:]CURRent:PROTection:STATe?
Returns: = 1 (enabled) or 0 (disabled)

Description: Indicates whether the current protection level set using CURR:PROT is enabled (1) or disabled

(0).

B.49 [SOURce:]CURRent:RANGe COMMAND

CURR:RANG

Syntax:

Short Form: [SOUR:]CURR:RANG

Long Form: [SOURce:]CURRent:RANGe

where: = 0, 1, 2, 3 or 4

Description: Controls the placement of the decimal point during remote interface readback of current, and

on the front panel AMPS display when showing current. Display Ranges: 0 - Auto, 1 - 0.000, 2 -
00.00, 3 - 000.0, 4 - 0000.

B.50 [SOURce:]CURRent:RANGe? QUERY

CURR:RANG?

Syntax:

Short Form: [SOUR:]CURR:RANG?

Long Form: [SOURce:]CURRent:RANGe?

Returns: = 0, 1, 2, 3 or 4

Description: Indicates the placement of the decimal point during remote interface readback of current, and

on the front panel AMPS display when showing current. Display Ranges: 0 - Auto, 1 - 0.000, 2 -
00.00, 3 - 000.0, 4 - 0000.

B.51 [SOURce:]FUNCtion COMMAND

FUNC

Syntax:

Short Form: [SOUR:]FUNC

Long Form: [SOURce:]FUNCtion

where: = CURR, POW, VOLT, RES, COND or OFF

Description: Sets operating mode.

B.52 [SOURce:]FUNCtion QUERY

FUNC?

Syntax:

Short Form: [SOUR:]FUNC?>

Long Form: [SOURce:]FUNCtion?

Returns: = CURR, POW, VOLT, RES, COND or OFF

Description: Indicates operating mode.

B.53 [SOURce:]MODE COMMAND

MODE

Syntax:

Short Form: [SOUR:]MODE

Long Form: [SOURce:]MODE

where: = CURR, POW, VOLT, RES, COND, SHORT or OFF

Description: Sets operating mode: CURRent, POWer, VOLTage, RESistance, CONDuctance, SHORT or OFF.

B.54 [SOURce:]MODE? QUERY

MODE?

Syntax:

Short Form: [SOUR:]MODE?

Long Form: [SOURce:]MODE?

Returns: = CURR, POW, VOLT, RES, COND, SHORT or OFF

Description: Indicates the present mode: CURRent, POWer, VOLTage, RESistance, CONDuctance, SHORT or

OFF.

B.55 [SOURce:]POWer[:LEVel][:IMMediate][:AMPlitude] COMMAND

POW

Syntax:

Short Form: [SOUR:]POW[:LEV][:IMM][:AMP]
Long Form: [SOURce:]POWer[:LEVel][:IMMediate][:AMPlitude]
Where = power setpoint

Description: Establishes power setpoint.