50

Absolute Amplitude Accuracy

Absolute Point

Center=160 MHz ; RBW 10 kHz; VBW 1 kHz;
span 100 kHz; log scale; 1 dB/div; peak
detector; 20 to 30°C; signal 0 dBm

Preamp off

± 0.3 dB

Ref level 0 dBm;
10 dB RF attenuation

Preamp on

± 0.4 dB

Ref level -30 dBm;
0 dB RF attenuation

Frequency Response

Preamp off

Attenuation: 10 dB; Reference: 160 MHz; 20 to
30°C

100 kHz to 2.0
GHz

± 0.5 dB

2.0GHz to 3.0
GHz

± 0.7 dB

Preamp on

Attenuation: 0 dB; Reference: 160 MHz; 20 to
30°C

1 MHz to 2.0
GHz

± 0.6 dB

2.0GHz to 3.0
GHz

± 0.8 dB

Attenuation Switching Uncertainty

Attenuator setting 0 to 50 dB in 1 dB step

Uncertainty

± 0.15 dB

reference: 160 MHz,
10dB attenuation

RBW Filter Switching Uncertainty

10 Hz to 1 MHz ± 0.15 dB

reference : 10 kHz
RBW

Level Measurement Uncertainty

Overall Amplitude
Accuracy

± 1.5 dB

20 to 30°C; frequency > 1 MHz;
Signal input 0 to -50 dBm;
Reference level 0 to -50 dBm;
Input attenuation 10 dB;
RBW 1 kHz;
VBW 1 kHz; after cal; Preamp Off

± 0.5 dB

Typical