beautypg.com

Edwards Signaling 108-DN Series User Manual

Page 3

background image

P/N 3100179 ISSUE 1

PAGE 3

BYTE

BIT7

BIT6

BIT5

BIT4

BIT3

BIT2

BIT1

BIT0

0

DON'T

DON'T

DON'T

DON'T

DON'T

LED 3

LED 2

LED 1

CARE

CARE

CARE

CARE

CARE

1 = ON

1 = ON

1 = ON

0 = OFF

0 = OFF

0 = OFF

1

0

0

1

DON'T

DON'T

LED 3

LED 2

LED 1

45

CARE

CARE

1 = FLSH

1 = FLSH

1 = FLSH

FPM

0 = STDY

0 = STDY

0 = STDY

1

0

1

0

DON'T

DON'T

LED 3

LED 2

LED 1

60

CARE

CARE

1 = FLSH

1 = FLSH

1 = FLSH

FPM

0 = STDY

0 = STDY

0 = STDY

1

1

DON'T

DON'T

DON'T

DON'T

LED 3

LED 2

LED 1

80

CARE

CARE

CARE

CARE

1 = FLSH

1 = FLSH

1 = FLSH

FPM

0 = STDY

0 = STDY

0 = STDY

1

0

0

0

DON'T

DON'T

LED 3

LED 2

LED 1

80 FPM

80 FPM

80 FPM

CARE

CARE

1 = FLSH

1 = FLSH

1 = FLSH

DEFLT

DEFLT

DEFLT

0 = STDY

0 = STDY

0 = STDY

2

0

0

0

0

Sounder

Tone

Tone

Tone

1 = ON

MSB

LSB

0 = OFF

Output to the base with the poll command from master node.

Data Byte 0 value indicates the LEDs to be turned ON or OFF.
Data Byte 1 value indicates the ON LEDs to be Steady ON or Flashing and the Flashing rate (45, 60 or 80 flashes per

minute) selected.
Data Byte 2 value indicates the sounder to be turned ON or OFF and the tone to be chosen.

2.0 Standard Objects.
2.1 Identity Object (Class ID = 1).

There is a single instance of the identity object for the Chameleon DeviceNet Status Indicator. No class attributes

are supported. All of the instance attributes are contained in rom and are gettable but not settable. The table

below shows the values.

ATTRIBUTE

ACCESS

DATA

ID

RULES

NAME

TYPE

VALUE

1

Get

Vendor Code

Uint

0x201 (513)

2

Get

Product Type

Uint

0x0000

3

Get

Product Code

Uint

0x0001

4

Get

Revision

Word

01.01

5

Get

Status

UDINT

0x0000

6

Get

Serial #

Uint

UNIQUE SERIAL #

7

Get

Product Name

STRUCT

102

Identity Object Services:

SERVICE

SERVICE CODE

PARAMETERS

Get Attribute Single

0x0E

Attribute ID

Reset

0x05

0, 1