beautypg.com

Ft5000 – Triton FT5000 PC-BASED ATM Installation Manual User Manual

Page 26

background image

26

FT5000

XP

- S

ITE

P

REPARATION AND

I

NSTALLATION

G

UIDE

S

ECURING

U

NIT

It’s recommended that the unit be secured to the facility floor and plinth structure.

If a plinth was used, we recommend anchoring that structure first due to accessibil-

ity may be limited once the unit is mounted on the plinth. The footprint of the

cabinet floor allows for securing to either a concrete pad or plinth structure. An-

chor bolts may be too short to go straight from the cabinet to the floor, depending

how high the unit was raised to accommodate the wall opening. It is the customer

or their agent’s responsibility to determine how the unit is af fixed to the facility.

Listed are some general considerations when securing the unit:

LEVEL FLOORING

REQUIREMENT

It is very important that the ATM

cabinet be located on flat, level

flooring! If the floor is not flat

and level, the cabinet bottom and/

or walls may become distorted

when the mounting bolts are tight-

ened down! This could prevent

the security vault door from clos-

ing!

1. What is the floor structure?

(concrete, wood, etc) Do you have

anchors, lag bolts, screws to secure

cabinet/plinth?

2. Is the unit a UL Level 1 Safe cabinet

or Business Hours? Will the floor

support the weight of the cabinet?

What is the plinth constructed of?

(If you build -concrete, metal, wood,

etc).

3. Is the inside floor level the same as

the outside ground? If inside floor

is higher or lower than outside, will

you need the optional 2-3/8” or 4-

3/4” plinths?

4. Is the floor level? Will the unit need

to be raised using the plinth/cabinet

leveling feet? (Leveling feet are for

minimal corrections to level cabinet)

5. Is exterior wall solid? (brick,

concrete) W ood framed?

Aluminum siding? Do you need to

insulate the wall cavity?

6. After cabinet is anchored, is the

control panel trim flush against the

exterior wall? Is the trim sufficiently

sealed to prevent moisture from

entering the control panel

electronics?

LEVEL 1 CABINET SAFETY

Level 1 cabinets are consider-

ably heavier than Business Hours

cabinets! Exercise extreme cau-

tion when moving Level 1 cabi-

nets! At least two persons should

work together to move the cabi-

net into position for mounting!

TOOL USE/SAFETY

Observe ALL safety precautions

for operating hand and power

tools! Wear eye and ear protec-

tion while operating the electric

drill!

USE A BACK-SUPPORT BELT

WHEN LIFTING AND MOVING

THE ATM!