Atm i, 34 automated teller machines, 3 reach ranges – Triton FT5000 PC-BASED ATM Installation Manual User Manual

Page 10: Ft5000

background image

10

ATM I

NSTALLATION FOR

A

CCESSIBILITY

1. This document supersedes all other

information provided by Triton for

ATM installation for accessibility.

2. Information provided in this

manual is based on federal guide-

lines (ADA Accessibility Guidelines

for Buildings and Facilities –

ADAAG) as amended through

January 1998. You should verify it

has not been amended. States may

also have accessibility codes.

These codes may be more restric-

tive than the federal guidelines.

Please verify this with the state

where the ATM is to be installed

prior to installation. For state con-

tact information, you may call the

ADA information line at 1-800-514-

0301.

3. For countries other than the US,

please use the guidelines for ac-

cessibility for that country.

4. A complete copy of the ADAAG

referred to here can be found at

http://www.access-board.gov.

In-

cluded in this document is the sec-

tion of the ADAAG specifically for

ATMs. For additional information

on floor surfaces and other

ADAAG requirements, please see

the complete specification.

4.34 Automated Teller

Machines.

4.34.1 General. Each machine re-

quired to be accessible by 4.1.3

(Accessible Buildings: New Con-

struction) shall be on an accessible

route and shall comply with 4.34

(Automated Teller Machines).

4.34.2 Clear Floor Space. The auto-

mated teller machine shall be lo-

cated so that clear floor space com-

plying with 4.2.4 (Clear Floor or

Ground Space for Wheelchairs)

is provided to allow a person using

a wheelchair to make a forward ap-

proach, a parallel approach, or both

to the machine.

4.34.3 Reach Ranges.

(1) Forward Approach Only. If only a

forward approach is possible, operable

parts of all controls shall be placed within

the forward reach range specified in

4.2.5 (Forward Reach).

(2) Parallel Approach Only. If only a

parallel approach is possible, operable

parts of controls shall be placed as fol-

lows:

(a) Reach Depth Not More Than 10

inches (255 mm). Where the reach

depth to the operable parts of all con-

trols as measured from the vertical plane

perpendicular to the edge of the unob-

structed clear floor space at the farthest

protrusion of the automated teller ma-

chine or surround is not more than 10

inches (255 mm), the maximum height

above the finished floor or grade shall

be 54 inches (1370 mm).