Atm e – Triton FT5000 PC-BASED ATM Installation Manual User Manual

Page 18

background image

18

ATM E

NVIRONMENTAL

P

RECAUTIONS

C

HECKLIST

TEMPERATURE/HUMIDITY

1. The ATM will operate over a range

of temperatures and humidity.

Generally, these parameters must

fall within the following ranges:

Temperature (Interior)

10°C - 40°C

50°F - 104° F

Relative Humidity

20% - 80%

(Non-Condensing)

Temperature (Exterior)

AC POWER REQUIREMENTS

2. Ensure the following AC power

requirements are met:

Current (Max)

5.05A @ 120V

2.01A @ 240V

Voltage

90V - 136V @ 50/60 Hz

198V - 257V @ 50/60 Hz

Power Consumption (Idle)

2.0A @ 115 VAC at 60 Hz

1.0A @ 230 VAC at 50 Hz

Isolated G round. An equipment

grounding conductor that is insulated

from the conduit or raceway and all

other grounding points throughout its

entire length. The only points of elec-

trical connection will be at the duplex

outlet and service panel ends of the

line.

-35°C - 50°C

-30°F - 122°F

Relative Humidity

20% - 100%

Dedicated source. The ATMs AC

power feed will be a dedicated line to

which no other electrical devices are

connected. The ATM power line will

be wired for a single “duplex”-style

outlet and connected directly to the

AC service panel.

Power Consumption (Max Load)

606 Watts @ 120V

482 Watts @ 240V

When installing an ATM, some general environmental and power precau-

tions need to be considered. Evaluate the location where the ATM will be

installed. To help ensure proper operation of the ATM, ensure the environ-

mental criteria listed in this checklist are met.

RF INTERFERENCE

3. Ensure there are no devices near

the terminal that may cause RF in-

terference, such as:

‰

TVs

‰

Coolers

‰

Security Devices

‰

Neon Signs

‰

Devices with Compressors

* IMPORTANT *

AC power for the terminal should

come from a dedicated source with

an isolated ground.