Atm e – Triton FT5000 PC-BASED ATM Installation Manual User Manual
Page 18
18
ATM E
NVIRONMENTAL
P
RECAUTIONS
C
HECKLIST
TEMPERATURE/HUMIDITY
1. The ATM will operate over a range
of temperatures and humidity.
Generally, these parameters must
fall within the following ranges:
Temperature (Interior)
•
10°C - 40°C
•
50°F - 104° F
Relative Humidity
•
20% - 80%
•
(Non-Condensing)
Temperature (Exterior)
AC POWER REQUIREMENTS
2. Ensure the following AC power
requirements are met:
Current (Max)
•
5.05A @ 120V
•
2.01A @ 240V
Voltage
•
90V - 136V @ 50/60 Hz
•
198V - 257V @ 50/60 Hz
Power Consumption (Idle)
•
2.0A @ 115 VAC at 60 Hz
•
1.0A @ 230 VAC at 50 Hz
Isolated G round. An equipment
grounding conductor that is insulated
from the conduit or raceway and all
other grounding points throughout its
entire length. The only points of elec-
trical connection will be at the duplex
outlet and service panel ends of the
line.
•
-35°C - 50°C
•
-30°F - 122°F
Relative Humidity
•
20% - 100%
Dedicated source. The ATMs AC
power feed will be a dedicated line to
which no other electrical devices are
connected. The ATM power line will
be wired for a single “duplex”-style
outlet and connected directly to the
AC service panel.
Power Consumption (Max Load)
•
606 Watts @ 120V
•
482 Watts @ 240V
When installing an ATM, some general environmental and power precau-
tions need to be considered. Evaluate the location where the ATM will be
installed. To help ensure proper operation of the ATM, ensure the environ-
mental criteria listed in this checklist are met.
RF INTERFERENCE
3. Ensure there are no devices near
the terminal that may cause RF in-
terference, such as:
TVs
Coolers
Security Devices
Neon Signs
Devices with Compressors
* IMPORTANT *
AC power for the terminal should
come from a dedicated source with
an isolated ground.