beautypg.com

Conventional building – Hired-Hand System 1000 Power Curtain Eight Stage Controller User Manual

Page 33

background image

System 1000™ Power Curtain™ Controller

30

17.2. Conventional Building

Conventional houses have different ventilation needs than do tunnel ventilated houses.
In the example below our house will be set up as follows:

H1

H2

H3

H4

H5

F6

F1

F2

F3

F4

F5

F7

F8

F9

F10

F11

F12

S1

S2

S3

S4

Stage

Mode

Equipment

Sensors

Offset

Diff

On Timer

1

Heat

H-1,2,3

1,2

3

1

---

2

Heat

H-4,5

3

3

1

---

3

Cool-Neg

F-2,5

1,2

1

1

Yes

4

Cool-Neg

F-1,3

3

3

1

Yes

5

Cool-Neg

F-4,6

1,2,3

3

1

No

6

Cool Stir

F-7,8,9

1,2,3

6

1

No

7

Cool Stir

F-10,11,12

1,2,3

6

1

No

8

Lighting

Lights

--

--

--

--

1.

Variable Timer
A.

Hi Temp................................................................ 70

B.

Hi Percent ............................................................. 60

C.

Lo Temp ............................................................... 40

D.

Lo Percent............................................................. 20

2.

Ramp Function .............................................................. Yes
A.

Number Of Days ................................................... 30

B.

Ending Temperature ............................................. 72

3.

Setup System ................................................................. Yes
A.

Sensors For Display .............................................. 1,2,3

B.

Unit Sensor(s) ....................................................... 1,2,3

C.

Auto Kill Fans ...................................................... Yes

D.

Power Unit............................................................ On

4.

Program Stages.............................................................. Yes
A.

Program Stage 1.................................................... Yes
1.

Mode .......................................................... Heat

2.

Stage 1 Sensors........................................... 1,2

3.

Stage 1 Offset ............................................. 3

4.

Stage 1 Differential..................................... 1

B.

Program Stage 2.................................................... Yes
1.

Mode .......................................................... Heat

2.

Stage 2 Sensors........................................... 3

3.

Stage 2 Offset ............................................. 3

4.

Stage 2 Differential..................................... 1

C.

Program Stage 3.................................................... Yes
1.

Mode .......................................................... Cool-Neg

2.

Stage 3 Sensors........................................... 1,2,3

3.

Stage 3 Offset ............................................. 1