Hired-Hand System 1000 Power Curtain Eight Stage Controller User Manual
Page 28

System 1000™ Power Curtain™ Controller
25
3.
Stage 2 Offset
4.
Stage 2 Differential
5.
* Stage on Timer
C.
Program Stage 3
1.
Mode
2.
Stage 3 Sensors
3.
Stage 3 Offset
4.
Stage 3 Differential
5.
* Stage on Timer
D.
Program Stage 4
1.
Mode
2.
Stage 4 Sensors
3.
Stage 4 Offset
4.
Stage 4 Differential
5.
* Stage on Timer
E.
Program Stage 5
1.
Mode
2.
Stage 5 Sensors
3.
Stage 5 Offset
4.
Stage 5 Differential
5.
* Stage on Timer
F.
Program Stage 6
1.
Mode
2.
Stage 6 Sensors
3.
Stage 6 Offset
4.
Stage 6 Differential
5.
* Stage on Timer
G.
Program Stage 7
1.
Mode
2.
Stage 7 Sensors
3.
Stage 7 Offset
4.
Stage 7 Differential
5.
* Stage on Timer
H.
Program Stage 8
1.
Mode
2.
Stage 8 Sensors
3.
Stage 8 Offset
4.
Stage 8 Differential
5.
* Stage on Timer
5.
Setup Var. Speed
A.
Max Speed
B.
Maximum Offset
C.
Minimum Speed
D.
Minimum Offset
Var Speed Sensors
6.
Light Strip Control
A.
Begin Cycle
B.
In. to Drop
C.
First Drop
D.
End Cycle
E.
Nite Vent Program
1.
Begin Cycle
2.
End Cycle
7.
Artificial Light
A.
Start Cycle
If OSC High mode is used, stage 7
or 8 must be reserved. If Artificial
light is used, it will only operate
from stage 8. Thus if both features
are used, you must reserve both
stage 7 and 8 for this reason.
- Polar Cool: Portable Evaporative Cooling System (22 pages)
- Polar Cool: External Control Box (4 pages)
- Polar Cool: Pump & Float Replacement (2 pages)
- Polar Cool: PUMP REPLACEMENT (4 pages)
- Polar Cool: Wall Mount Kit (4 pages)
- Unitized Mega Cool (68 pages)
- Unitized Mega Cool: Square Bottom (63 pages)
- Mega-Cool: Square Reservoir (24 pages)
- Mega-Cool rev 6-09 (46 pages)
- Mega-Cool: Mega-Cool Pad Extender Kit (5 pages)
- Mega-Cool: Float Valve Replacement (1 page)
- Mega-Cool: Float Valve (Topaz) Replacement (1 page)
- Mega-Cool: In-Line Pump Motor Replacement (2 pages)
- Var-O-Matic (2 pages)
- System 1000 Power Vent (31 pages)
- System 1000 Power Vent (13 pages)
- System 500 Programs (Conventional Model) (5 pages)
- System 100 Variable Speed Controller (7 pages)
- System 500 Programs (Tunnel Model) (7 pages)
- System 1000 Power Curtain (17 pages)
- System 2000 AUTO TEMP (10 pages)
- System 2001 Power Curtain Controller (43 pages)
- System 500 Power Curtain Controller (31 pages)
- ICS-500 Environmental Controller (34 pages)
- Pressure Transducer Changeout (1 page)
- HH Software: HH.Net Router/Repeater (8 pages)
- HH Software: 900SS Wireless Network (10 pages)
- HH Software: Farm Manager (22 pages)
- HH Software: Data Shuttle Launch Pad (25 pages)
- Sens-O-Matic (Feed Hopper Switch) (2 pages)
- Manual Light Dimmer (2 pages)
- Electro Mechanical Controls (Relay-Switches): PHOTOHELIC POWER VENT (10 pages)
- Electro Mechanical Controls (Relay-Switches): PT Controller (9 pages)
- Electro Mechanical Controls (Relay-Switches): PC-DB Curtain Controller with DIF (6 pages)
- Electro Mechanical Controls (Relay-Switches): PC-DB Curtain Controller with Timer Override (7 pages)
- Electro Mechanical Controls (Relay-Switches): Photohelic Gauge (1 page)
- Feed Management System (15 pages)
- Contactor Control System (CCS): 4, 8, or 12 Stage (19 pages)
- Contactor Control System (CCS): Triple Pole 16-Stage (7 pages)
- Contactor Control System (CCS): Vent Machine Override 3 Wire PowerTrak (1 page)
- Evolution 4000 Control System (86 pages)
- Evolution Series 1200: Variable Output With Override Pot (14 pages)
- Evolution Series 1200: Variable Output (12 pages)
- Evolution Series 1200 (64 pages)