7.6 Bottom Pipe Assembly
NOTE: Motor drive will attach to bottom pipe.
The bottom pipe is composed of 21 ft. (640 cm) sections that connect together with pop rivets.
1.
Lay bottom pipe sections on the ground end-to-end with the swedged end of one pipe section facing open
end of adjacent pipe section.
2.
Connect pipe sections together by sliding the swedged end of one pipe section into open end of adjacent
pipe section. (NOTE: It might be necessary to take a hammer and straighten out the dimples which were
created when the pipe sections were cut). Attach the sections together by installing stainless steel pop
rivets as shown in diagram above and described below.
3.
Pop rivet installation. Drill three 3/16 in. (0.48 cm) diameter holes through pipe joint. Space holes equally
around pipe. Insert pop rivets through these holes to fasten the pipe sections together.
Bottom Conduit Pipe
(1060-6004)
1.315" (3.34 cm) dia.
Diagram showing completed joint of pipe with pop rivets
(third pop rivet not visible in this drawing)
Pop rivet
Open end of pipe
Swedged end of pipe
- RollSeal Rolling Dampers (5 pages)
- RollSeal Rollup Curtains: Ridder Motor Control (9 pages)
- RollSeal Rollup Curtains: RollSeal Motor Controls (16 pages)
- RollSeal Rollup Curtains: ROLLUP CURTAIN SYSTEM Rev 12-07 (26 pages)
- RollSeal Sidewall System (Curtain): SideWall Curtain (38 pages)
- RollSeal Sidewall System (Curtain): Wiring Diagram And Limit Switches (2 pages)
- RollSeal Sidewall System (Curtain): Floating Hook & Loop Assembly (2 pages)
- Light Traps: Light Trap Fan Unit (2 pages)
- Light Traps: Light Trap Adapter Kit (2 pages)
- Light Traps: 54x54 Light Trap Air Inlet (2 pages)
- Light Traps: 7x44 - 8x44 Light Trap Air Inlet (1 page)
- Light Traps: Light Trap Vent Box Installation (1 page)
- Light Traps: Installing Continuous Light Trap (6 pages)
- Light Traps: Installing Light Trap for Fan (4 pages)
- Light Traps: Light Trap Fan Unassembled (4 pages)
- Baffles, Vents, & Inlets: VENT DOORS Installation (2 pages)
- Baffles, Vents, & Inlets: GRAVITY VENT DOOR Installation (2 pages)
- Baffles, Vents, & Inlets: SINGLE CEILING INLET (2 pages)
- Baffles, Vents, & Inlets: 24 & 36 Chimney Vent (12 pages)
- Baffles, Vents, & Inlets: Vent Kit for Generation Structures (8 pages)
- Baffles, Vents, & Inlets: QUAD CEILING INLET (2 pages)
- Baffles, Vents, & Inlets: Ridge Vent Assembly Instructions (2 pages)
- Baffles, Vents, & Inlets: Installing Ceiling Inlets (2 pages)
- Tunnel Doors (16 pages)
- Circulation and Stir Fans: MEGA-FLOW FANS (See Reverse Side for Framing Formats) (2 pages)
- Circulation and Stir Fans: MEGA-FLOW 24 INCH ORIFICE STIR FANS (2 pages)
- Circulation and Stir Fans: MEGA-FLOW ORIFICE FANS (2 pages)
- Circulation and Stir Fans: Post Mount Assembly For 52 Orifice Fans (4 pages)
- Circulation and Stir Fans: Funnel Flow Fan (1 page)
- Circulation and Stir Fans: MEGA FLOW FANS Round Dairy Fan (2 pages)
- Circulation and Stir Fans: 48 MEGA FLOW (2 pages)
- Circulation and Stir Fans: 48 MEGA FLOW Galvanized (2 pages)
- Circulation and Stir Fans: MEGA FLOW 36 (91 cm) Fan Housing (2 pages)
- Circulation and Stir Fans: 48 MEGA FLOW Fan Housing (2 pages)
- Circulation and Stir Fans: 52 Orifice Fan HSP Conversion Kit (2 pages)
- Circulation and Stir Fans: HAF Fan Mounting Bracket Installation (2 pages)
- Circulation and Stir Fans: POST MOUNT KIT ASSEMBLY (2 pages)
- Circulation and Stir Fans: MEGA FLOW Motor Replacement 36 (91 cm) Fan Housing (2 pages)
- Mega Flow Panel Fans: Econo-Flow 48 Belt Drive Panel Fan (2 pages)
- Mega Flow Panel Fans: Power Cord Installation (2 pages)
- Mega Flow Panel Fans: BELT TENSIONER 48 Mega Flow Fan (1 page)
- Funnel Flow Fans: Belt Tensioner (2 pages)
- Funnel Flow Fans Rev 12-03 (2 pages)
- Funnel Flow Fans Rev 10-98 (1 page)