Installation precautions and warnings, Determining which power supply failed, Ac power supplies – Brocade FastIron GS and GS-STK Hardware Installation Guide User Manual
Page 98: Dc power supplies
88
Brocade FastIron GS and GS-STK Hardware Installation Guide
53-1002186-02
Replacing a power supply
8
DRAFT: BROCADE CONFIDENTIAL
Installation precautions and warnings
Follow these precautions when installing a power supply in the FGS and FGS-STK device.
DANGER
Before beginning the installation, refer to the precautions in
Do not install the device in an environment where the operating ambient temperature might exceed
40 Deg. Celsius C (104 Deg. F).
CAUTION
Never leave tools inside the device.
Determining which power supply failed
If you are replacing a power supply that has failed and you are not sure which supply has failed,
enter the following command at any CLI command prompt:
This command displays status information for the power supplies and the fans. The power supplies
are numbered from left to right. These numbers assume you are facing the front of the device, not
the rear.
If the display indicates “Installed (Failed)” for any of the slots, the power supply installed in that
particular slot has failed.
AC power supplies
If you need to install or replace an AC power supply, refer to the procedures on
DC power supplies
if you need to install or replace a DC power supply, refer to
“Installing a DC power supply”
FastIron>show chassis
power supply 1
power supply 2 not present
Fan 1 ok
Fan 2 ok
Exhaust Side Temperature Readings:
Current temperature : 28.5 degrees Celsius
Warning level.......: 45.0 degrees Celsius
Shutdown level......: 55.0 degrees Celsius
Intake Side Temperature Readings:
Current temperature : 29.0 degrees Celsius
Boot Prom MAC: 00e0.5200.0100