Environmental considerations, Cooling, Draft: brocade confidential – Brocade FastIron GS and GS-STK Hardware Installation Guide User Manual
Page 78
68
Brocade FastIron GS and GS-STK Hardware Installation Guide
53-1002186-02
Device specifications
6
DRAFT: BROCADE CONFIDENTIAL
Environmental considerations
For optimal performance, operate or store your Brocade FGS or FGS-STK device in compliance with
the following environmental conditions.
Cooling
FGS or FGS-STK devices have two single-speed fans that operate simultaneously to cool the CPU,
main memory, and voltage regulators. If one fan fails, it does not affect the operation of the other
fan. The fans use either a push or pull configuration to move the air from the left side of the device
to the right side of the device as shown in
FIGURE 47
Device air flow
2
TABLE 13
Environmental Conditions for the Device
Description
Range
Operating Environment
Operating temperature
32
– 104
F (0
– 40
C)
Operating altitude
6,600 feet maximum
Relative humidity
5 to 95%, @ 104
F (40
C), non-condensing
or
5 to 95% non-condensing for DC power supply
Operating noise
47 – 51 dB
Maximum heat
dissipation
328 BTU/Hr with 2-port 10-Gigabit uplinks
280 BTU/Hr without 2-port 10-Gigabit uplinks
Storage Environment
Storage temperature
-23
to 158
F, -25
to 70
C
Storage humidity
95% maximum, non-condensing
Storage altitude
15,000 feet ( 3,000 meter) maximum
1
Air intake
Air outflow
26
25
X4-2XG
1
2