Mean time between failure, Power draw specifications, Draft: brocade confidential – Brocade FastIron GS and GS-STK Hardware Installation Guide User Manual
Page 80
70
Brocade FastIron GS and GS-STK Hardware Installation Guide
53-1002186-02
Device specifications
6
DRAFT: BROCADE CONFIDENTIAL
Mean Time Between Failure
lists the Mean Time Between Failure (MTBF) for the FastIron GS, FastIron GS-STK, and 10
Gbps uplink modules. The MTBF is the average estimated time, in hours, before a hardware failure
may occur.
Power draw specifications
lists the typical and maximum power draw specifications for FGS and FGS-STK models.
TABLE 15
Device Power Surge and Drop Protection
Property
Protection Mechanism
Power surge
MOV and Spark Gap protection
Power drop (<=1 second)
An AC loss of >15ms will cause the power supply to shut
down due to input under-voltage
Maximum power draw
96 watts with 2-port 10-Gigabit uplinks
82 watts without 2-port 10-Gigabit uplinks
TABLE 16
MTBF for the FastIron GS and GS-STK and 10 Gbps Modules
Configuration/Module
Temperature
MTBF (hours)
Without POE
With POE
24-port POE ready + 4 SFPs + 2-port 10 Gbps
module + 2 XFPs + 1 power supply
40 Deg. Celsius
150,879
142,217
24-port POE ready + 4 SFPs + 2-port 10 Gbps
module + 2 XFPs + 2 powers supplies
40 Deg. Celsius
267,411
241,356
48-port POE ready + 4 SFPs + 2-port 10 Gbps
module + 2 XFPs + 1 power supply
40 Deg. Celsius
133,825
120,775
48-port POE ready + 4 SFPs + 2-port 10 Gbps
module + 2 XFPs + 2 power supplies
40 Deg. Celsius
218,140
196,401
2-port 10 Gbps XFP module
40 Deg. Celsius
1,597,580
N/A
2-port 10 Gbps CX4 module
40 Deg. Celsius
N/A
29,673,590
1-port 10 Gbps XFP + 1-port 10 Gbps CX4 module
40 Deg. Celsius
N/A
2,364,614
1-port 10 Gbps XFP module
40 Deg. Celsius
N/A
2,501,219