Upgrading hardware – Brocade FastIron GS and GS-STK Hardware Installation Guide User Manual
Page 56
46
Brocade FastIron GS and GS-STK Hardware Installation Guide
53-1002186-02
Upgrading hardware
4
DRAFT: BROCADE CONFIDENTIAL
Upgrading hardware
You need a Phillips-head screwdriver and an ESD wrist strap to perform this procedure. You also
need a static-free work area.
To perform the upgrade:
1. Remove all power cables from the device.
2. Remove the device from the equipment rack, if necessary, and place the device in a static-free
work area.
3. Put on the supplied ESD wrist strap and attach the clip end to a metal surface (such as an
equipment rack) to act as ground.
4. Disassemble the device as follows (refer to
•
Use a Phillips-head screwdriver to remove the two screws in the bottom corners of each
side. If rack mounting ears are installed, remove the four screws that hold each ear to the
device. Refer to
•
Turn the device so that the front (where the port connectors are) is facing you.
•
Slide the cover backwards to free the lip edge of the cover from the front plate. Make sure
the cover is completely free of the front panel.
.5 meter CX4 cable
Upgrade label
Upgrade label
TABLE 8
Upgrade kit contents (Continued)
Kit with CX4 Module:
FGS624-STK-CXU, FGS648-STK-CXU,
Kit without CX4 Module:
FGS624-STK-U, FGS648-STK-U
WARNING
Disconnect the power cord from all power sources to completely remove power from the
device.
ACHTUNG
Ziehen Sie das Stromkabel aus allen Stromquellen, um sicherzustellen, dass dem Gerät
kein Strom zugeführt wird.
AVERTISSEMENT
Débranchez le cordon d'alimentation de toutes les sources d'alimentation pour couper
complètement l'alimentation du dispositif.
ADVERTENCIA
Para desconectar completamente la corriente del instrumento, desconecte el cordón de
corriente de todas las fuentes de corriente.