Regulatory certifications, Environmental regulation compliance, Table 16 – Brocade VDX 6730 Hardware Reference Manual (Supporting VDX 6730-32 and VDX 6730-76) User Manual
Page 82
64
Brocade VDX 6730 Hardware Reference Manual
53-1002389-06
Regulatory certifications
A
CAUTION
For a DC system, use a grounding wire of at least 14 American Wire Gauge (AWG). The 14 AWG
wire should be attached to an agency-approved crimp connector (Tyco 34120 or certified Lug),
crimped with the proper crimping tool and attached to the protective grounding lug, using a size
#6-32 screw and a star washer, on the chassis with the other end to building ground. Each DC-DC
power supply must have a separate grounding cable.
Regulatory certifications
lists the regulatory compliance standards for which the Brocade VDX 6730 is certified.
Environmental regulation compliance
This section describes the
environmental regulatory compliance requirements for
the Brocade VDX 6730 switch.
TABLE 16
Regulatory compliance standards
Country
Standards
Agency certifications and markings
Safety
EMC
Safety
EMC
United States
Bi-Nat UL/CSA 60950-1
2nd Ed or latest
ANSI C63.4
cCSAus
FCC Class A and
Statement
Canada
Bi-Nat UL/CSA 60950-1
2nd Ed or latest
ICES-003 Class A
cCSAus
ICES A and Statement
Japan
CISPR22 and JEIDA
(Harmonics)
VCCI-A and Statement
European Union
EN60950-1 2nd or
latest
EN55022 and EN55024 TUV-GS
CE marking
Australia, New Zealand
EN55022 and CISPR22
or AS/NZS CISPR22
C-Tick mark
Argentina
IEC60950-1 2nd or
latest
“S” mark
Russia
IEC60950-1 2nd or
latest
51318.22-99 and
51318.24.99 or latest
GOST mark
GOST mark
Korea
KN22 and KN24
KCC mark Class A
China
GB4943-2001 and
GB9254-1998 or latest
GB17625.1-2003 or
latest
CCC logo
CCC logo
Taiwan
CNS 14336(94) or latest CNS 13438(95) or latest BSMI mark
BSMI mark