Brocade vdx 6730-32 features, Brocade vdx 6730-76 features – Brocade VDX 6730 Hardware Reference Manual (Supporting VDX 6730-32 and VDX 6730-76) User Manual
Page 20
2
Brocade VDX 6730 Hardware Reference Manual
53-1002389-06
Brocade VDX 6730 overview
1
•
Support for long-range and short-range SFP+ GbE transceivers
•
Support for optical cables and active twin axial (twinax) copper cables
•
Support for direct-attach copper cables
•
Support for inter-switch link (ISL) trunking
-
Frame-level hardware-based trunking (even distribution of frames across trunk links)
•
A reduced-depth, rack-mount design using existing rail kits (fixed, mid-mount, or Telco rack
mount kits
•
Extensive diagnostics and system-monitoring capabilities for enhanced high Reliability,
Availability, and Serviceability (RAS)
•
Optimized airflow (a choice of front-to-back or back-to-front flow)
•
A real-time clock (RTC) with battery
•
SEEPROM for switch identification
•
Voltage monitoring
•
Fan monitoring
•
Three temperature sensors
•
I
2
C interface to monitor and control environmental aspects
NOTE
Port numbering for the Brocade VDX 6730 begins with 1, not 0. Both the GbE and FC port sequences
begin with 1.
Brocade VDX 6730-32 features
Features specific to the Brocade VDX 6730-32 include:
•
1U form factor enclosure
•
16 10 GbE SFP+ ports (also configurable to 1 GbE) with 8 additional 10 GbE ports available for
a total of 24
•
Eight 8 Gbps FC ports
•
One forwarding ASIC
•
600 nanosecond (ns) port-to-port latency
•
15-inch depth
•
Dual, hot-swappable 250W AC power supplies with three integrated cooling fans each
•
Dual, hot-swappable 250W DC power supplies with three integrated cooling fans each
Brocade VDX 6730-76 features
Features specific to the Brocade VDX 6730-76 include:
•
2U form factor enclosure
•
40 10 GbE SFP+ ports (also configurable to 1 GbE) with 20 additional 10 GbE ports available
for a total of 60
•
Sixteen 8 Gbps FC ports
•
Nine forwarding ASICs arranged in a 3/6, core/edge configuration