Brocade VDX 6730 Hardware Reference Manual

55

53-1002389-06

Environmental requirements

A

Environmental requirements

Table 12

lists the acceptable environmental ranges for both operating and nonoperating (such as

during transportation or storage) conditions.

General specifications

Table 13

lists the general specifications for the Brocade VDX 6730 switches.

TABLE 12

Environmental requirements

Condition

Acceptable during operation

Acceptable during non-operation

Ambient
Temperature

0º to 40ºC (32º to 104ºF)

-25º to 70ºC (-13º to 158ºF)

Humidity

10% to 85% RH non-condensing, at
40ºC (104ºF)

10% to 90% RH non-condensing, at 70ºC
(158ºF)

Altitude

0 to 3 km (9,842 feet) above sea level

0 to 12 km (39,370 feet) above sea level

Shock

20 G, 6 ms, half-sine wave

33 G, 11 ms, half-sine wave, 3/eg Axis

Vibration

0.5 G sine, 0.4 gms random, 5-500 Hz

2.0 G sine, 1.1 gms random, 5-500 Hz

Airflow

Brocade VDX 6730-32

Maximum - 90.1 cmh (53 cfm)
Nominal - 59.5 cmh (35 cfm)

Brocade VDX 6730-76

Maximum - 195.4 cmh (115 cfm)
Nominal - 129.1 cmh (76 cfm)

N/A

Heat
dissipation

Brocade VDX 6730-32 - 447 BTU/hr
Brocade VDX 6730-76 - 1095 BTU/hr

N/A

TABLE 13

General specifications

Specification

Description

System architecture

Nonblocking shared-memory switch

System processor

1.3 GHz PowerPC

Aggregate switch I/O bandwidth

304 Gbps - Brocade VDX 6730-32
728 Gbps - Brocade VDX 6730-76

Port-to-port latency

Less than 600 nanoseconds on the same ASIC, 1.8 microseconds for
multi-ASIC