beautypg.com

Checksum error message, Cajunview v3.0, Cpu synchronization – Avaya P880 User Manual

Page 29: Legacy cli

background image

29

610-0184-095

June 14, 2001

Workaround:

Either:

Disable auto-negotiation

Use a patch cable that is longer that 5 meters

Enter the following Enhanced CLI command in legacy mode:

> port set NationalPhyMode . enable

The factory default for the National Phy Mode is Enable.

Checksum Error Message

Problem:

The following checksum error displays after you upgrade from 4.3.x
code to v5.x code:

Bad file header compressed checksum...transfer cancelled.

Workaround:

Ignore the checksum error and reboot the switch to upgrade the
software.

CajunView v3.0

CajunView v3.0 does not support 80-series hardware. CajunView
v4.0 will support 50-series hardware and 80-series hardware on
Cajun switch software code version 5.1 and later.

CPU Synchronization

Problem:

If you attempt to synchronize the active supervisor and redundant
supervisor while the supervisor is being heavily used, TFTP transfers
from the active supervisor to the redundant supervisor may time out
and fail.

Workaround:

Repeat the synchronization when use of the supervisor has
decreased.

Legacy CLI

Problem:

The Legacy CLI setup command does not save information that you
enter.