beautypg.com

Known problems and workarounds, Atm uplink modules, Command line interface (cli) – Avaya P880 User Manual

Page 18: Flood rate limiting

background image

610-0184-095

18

June 14, 2001

Known Problems and Workarounds

The following known problems and workarounds apply to Cajun
P550R, P580, P880, and P882 switches that are running switch
software, v5.2.2. If a known problem has a viable workaround, it
immediately follows the Problem statement. If the known problem
has no viable workaround, it is listed as a bulleted statement.

ARP

Problem:

50-Series and 80-Series modules lose ARPs after you perform an
initialization of NVRAM (

NVRAM init

).

Workaround:

Reboot the switch twice after performing an NVRAM init.

ATM Uplink Modules

The following problem has no workaround:

The 50-series ATM Uplink modules do not work in slot 16 or
slot 17 if you are using an 80-Series Supervisor module in a
Cajun P882 switch.

Command Line Interface (CLI)

The following problem has no workaround

The “!” character, when used as part of a CLI command, is
considered a comment by the Cajun switch software:

If you type “!” BEFORE a CLI command, the switch
ignores the command and returns you to the CLI prompt.

If you type “!” after a CLI command, the switch displays
an Invalid Command or Syntax Error error message.

Flood Rate Limiting

Problem:

The options for setting flood rate limiting on 80-series, 10/100
Ethernet modules and on 80-series, 100 Base-FX Ethernet modules
are incorrect. The correct rates are not available from the Web Agent
or CLI.