IM 01C22T02-01E

A-6

APPENDIX 1. LIST OF PARAMETERS FOR EACH BLOCK OF THE EJA

26

2026

SENSOR_CAL_
WHO

Set/indicate the name of the person responsible for the
last sensor calibration.

O/S

27

2027

SECONDARY_
VALUE

The secondary value (istatic pressure) of transducer.

28

2028

MPa

SECONDARY_
VALUE_UNIT

The engineering unit of secondary value.

29

2029

TERTIARY_
VALUE

The tertiary value (Temperature) of transducer.

30

2030

C

TERTIARY_
VALUE_UNIT

The engineering unit of tertiary value.

O/S

31

2031

Trim disable

TRIM_PV_ZERO

Trim disable:

Prohibit zero/span calibration

Trim enable:

Enable zero/span calibration

Trim data clear: Clear zero/span calibration

O/S

32

2032

0

TRIM_MODE

The trim zero of primary value.

O/S

33

2033

Enable

EXT_ZERO_
ENABLE

The permission of external SW for trim zero.

O/S

34

2034

Model code

MODEL

The model code.

35

2035

Specified at the time
of order

DISPLAY_MODE

The mode of display. 1=Engineering unit, 2=% display,
3=1/10@Engr. Unit, 4=1/100@Engr. Unit, 5=1/1000@Engr.
Unit, 6=1/10000@Engr. Unit, 7=1/1000000@Engr. Unit.

O/S

36

2036

1

DISPLAY_CYCLE

The cycle of display on LCD.

O/S

37

2037

Disable

ALARM_SUM

The current alert status, unacknowledged status,
unreported status and disabled status of the alarms
associated with the function block.

38

2038

TEST_1

Not used for EJA.

39

2039

TEST_2

Not used for EJA.

40

2040

TEST_3

Not used for EJA.

41

2041

TEST_4

Not used for EJA.

42

2042

TEST_5

Not used for EJA.

43

2043

TEST_6

Not used for EJA.

44

2044

TEST_7

Not used for EJA.

45

2045

TEST_8

Not used for EJA.

46

2046

TEST_9

Not used for EJA.

47

2047

TEST_10

Not used for EJA.

48

2048

TEST_11

Not used for EJA.

49

2049

TEST_12

Not used for EJA.

50

2050

TEST_13

Not used for EJA.

51

2051

TEST_14

Not used for EJA.

52

2052

TEST_15

Not used for EJA.

53

2053

TEST_16

Not used for EJA.

54

2054

TEST_17

Not used for EJA.

TA0103-2.EPS

O/S

25

2025

SENSOR_CAL_
DATE

Set/indicate the date of the last sensor calibration.

O/S

24

2024

SENSOR_CAL_
LOC

Set/indicate the location of the last sensor calibration.

23

2023

103: factory trim
standard calibration

SENSOR_CAL_
METHOD

The method of the last sensor calibration.

100=volumetric
101=static weight
102=dynamic weight
103=factory trim standard calibration
104=user trim standard calibration
105=factory trim special calibration
106=user trim special calibration
255=others

O/S

22

2022

Serial No.

SENSOR_SN

Serial number.

Relative

Index

Index

Explanation

Write Mode

Factory Default

Parameter Name