Yokogawa EJA115 User Manual
Page 44
IM 01C22T02-01E
A-6
APPENDIX 1. LIST OF PARAMETERS FOR EACH BLOCK OF THE EJA
26
2026
–
SENSOR_CAL_
WHO
Set/indicate the name of the person responsible for the
last sensor calibration.
O/S
27
2027
–
SECONDARY_
VALUE
The secondary value (istatic pressure) of transducer.
–
28
2028
MPa
SECONDARY_
VALUE_UNIT
The engineering unit of secondary value.
–
29
2029
–
TERTIARY_
VALUE
The tertiary value (Temperature) of transducer.
–
30
2030
C
TERTIARY_
VALUE_UNIT
The engineering unit of tertiary value.
O/S
31
2031
Trim disable
TRIM_PV_ZERO
Trim disable:
Prohibit zero/span calibration
Trim enable:
Enable zero/span calibration
Trim data clear: Clear zero/span calibration
O/S
32
2032
0
TRIM_MODE
The trim zero of primary value.
O/S
33
2033
Enable
EXT_ZERO_
ENABLE
The permission of external SW for trim zero.
O/S
34
2034
Model code
MODEL
The model code.
–
35
2035
Specified at the time
of order
DISPLAY_MODE
The mode of display. 1=Engineering unit, 2=% display,
3=1/10@Engr. Unit, 4=1/100@Engr. Unit, 5=1/1000@Engr.
Unit, 6=1/10000@Engr. Unit, 7=1/1000000@Engr. Unit.
O/S
36
2036
1
DISPLAY_CYCLE
The cycle of display on LCD.
O/S
37
2037
Disable
ALARM_SUM
The current alert status, unacknowledged status,
unreported status and disabled status of the alarms
associated with the function block.
–
38
2038
–
TEST_1
Not used for EJA.
–
39
2039
–
TEST_2
Not used for EJA.
–
40
2040
–
TEST_3
Not used for EJA.
–
41
2041
–
TEST_4
Not used for EJA.
–
42
2042
–
TEST_5
Not used for EJA.
–
43
2043
–
TEST_6
Not used for EJA.
–
44
2044
–
TEST_7
Not used for EJA.
–
45
2045
–
TEST_8
Not used for EJA.
–
46
2046
–
TEST_9
Not used for EJA.
–
47
2047
–
TEST_10
Not used for EJA.
–
48
2048
–
TEST_11
Not used for EJA.
–
49
2049
–
TEST_12
Not used for EJA.
–
50
2050
–
TEST_13
Not used for EJA.
–
51
2051
–
TEST_14
Not used for EJA.
–
52
2052
–
TEST_15
Not used for EJA.
–
53
2053
–
TEST_16
Not used for EJA.
–
54
2054
–
TEST_17
Not used for EJA.
–
TA0103-2.EPS
O/S
25
2025
SENSOR_CAL_
DATE
–
Set/indicate the date of the last sensor calibration.
O/S
24
2024
SENSOR_CAL_
LOC
–
Set/indicate the location of the last sensor calibration.
23
2023
103: factory trim
standard calibration
SENSOR_CAL_
METHOD
The method of the last sensor calibration.
100=volumetric
101=static weight
102=dynamic weight
103=factory trim standard calibration
104=user trim standard calibration
105=factory trim special calibration
106=user trim special calibration
255=others
O/S
22
2022
Serial No.
SENSOR_SN
Serial number.
–
Relative
Index
Index
Explanation
Write Mode
Factory Default
Parameter Name