Series 146 – Watlow Series 146 Retrofit User Manual
Page 86

Series 146
Series 146
Line
Voltage
Input
Temp Range
Control
Mode
Action
Output
Set Point
Mounting
Retrofit control
See Notes
Below
146E-2T1D-3100
230 VAC
T t/c
-328 to 662°F
High Limit
Auto Reset
10A Relay
Integral
DIN Rail
LV E6MW -328 0662 A
3, 6, 8
146E-2T1D-3100
230 VAC
T t/c
-200 to 350°C
High Limit
Auto Reset
10A Relay
Integral
DIN Rail
LV E6NW -200 0350 A
3, 6, 8
146E-2T1D-3200
230 VAC
T t/c
-328 to 662°F
High Limit
Auto Reset
10A Relay
Remote
DIN Rail
LV E5MW -328 0662 A
2, 3, 6, 8
146E-2T1D-3200
230 VAC
T t/c
-200 to 350°C
High Limit
Auto Reset
10A Relay
Remote
DIN Rail
LV E5NW -200 0350 A
2, 3, 6, 8
146E-2T1D-4100
230 VAC
T t/c
-328 to 662°F
Low Limit
Auto Reset
10A Relay
Integral
DIN Rail
LV E6MZ -328 0662 A
3, 6, 8
146E-2T1D-4100
230 VAC
T t/c
-200 to 350°C
Low Limit
Auto Reset
10A Relay
Integral
DIN Rail
LV E6NZ -200 0350 A
3, 6, 8
146E-2T1D-4200
230 VAC
T t/c
-328 to 662°F
Low Limit
Auto Reset
10A Relay
Remote
DIN Rail
LV E5MZ -328 0662 A
2, 3, 6, 8
146E-2T1D-4200
230 VAC
T t/c
-200 to 350°C
Low Limit
Auto Reset
10A Relay
Remote
DIN Rail
LV E5NZ -200 0350 A
2, 3, 6, 8
146E-2T1F-1100
230 VAC
T t/c
-328 to 662°F
High Limit
Manual Reset
10A Relay
Integral
DIN Rail
LV E6MU -328 0662 A
3, 6
146E-2T1F-1200
230 VAC
T t/c
-328 to 662°F
High Limit
Manual Reset
10A Relay
Remote
DIN Rail
LV E5MU -328 0662 A
2, 3, 6
146E-2T1F-2100
230 VAC
T t/c
-328 to 662°F
Low Limit
Manual Reset
10A Relay
Integral
DIN Rail
LV E6MY -328 0662 A
3, 6
146E-2T1F-2200
230 VAC
T t/c
-328 to 662°F
Low Limit
Manual Reset
10A Relay
Remote
DIN Rail
LV E5MY -328 0662 A
2, 3, 6
146E-2T1F-3100
230 VAC
T t/c
-328 to 662°F
High Limit
Auto Reset
10A Relay
Integral
DIN Rail
LV E6MW -328 0662 A
3, 6
146E-2T1F-3200
230 VAC
T t/c
-328 to 662°F
High Limit
Auto Reset
10A Relay
Remote
DIN Rail
LV E5MW -328 0662 A
2, 3, 6
146E-2T1F-4100
230 VAC
T t/c
-328 to 662°F
Low Limit
Auto Reset
10A Relay
Integral
DIN Rail
LV E6MZ -328 0662 A
3, 6
146E-2T1F-4200
230 VAC
T t/c
-328 to 662°F
Low Limit
Auto Reset
10A Relay
Remote
DIN Rail
LV E5MZ -328 0662 A
2, 3, 6
146E-3101-1000
24 VAC
100 ohm DIN
-73 to 600°C
High Limit
Manual Reset
8A Relay
Integral
DIN Rail
LV G6RU -073 0600 A
6, 8
146E-3101-1000
24 VAC
100 ohm DIN
-100 to 1112°F
High Limit
Manual Reset
8A Relay
Integral
DIN Rail
LV G6PU -100 1112 A
6, 8
146E-3101-1N00
24 VAC
100 ohm DIN
-73 to 600°C
High Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV G5RU -073 0600 A
2, 6, 8
146E-3101-1N00
24 VAC
100 ohm DIN
-100 to 1112°F
High Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV G5PU -100 1112 A
2, 6, 8
146E-3101-1P00
24 VAC
100 ohm DIN
-73 to 600°C
High Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV G5RU -073 0600 A
2, 6, 8
146E-3101-1P00
24 VAC
100 ohm DIN
-100 to 1112°F
High Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV G5PU -100 1112 A
2, 6, 8
146E-3101-1S00
24 VAC
100 ohm DIN
-73 to 600°C
High Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV G5RU -073 0600 A
2, 6, 8
146E-3101-1S00
24 VAC
100 ohm DIN
-100 to 1112°F
High Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV G5PU -100 1112 A
2, 6, 8
146E-3101-2000
24 VAC
100 ohm DIN
-73 to 600°C
Low Limit
Manual Reset
8A Relay
Integral
DIN Rail
LV G6RY -073 0600 A
6, 8
146E-3101-2000
24 VAC
100 ohm DIN
-100 to 1112°F
Low Limit
Manual Reset
8A Relay
Integral
DIN Rail
LV G6PY -100 1112 A
6, 8
146E-3101-2N00
24 VAC
100 ohm DIN
-73 to 600°C
Low Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV G5RY -073 0600 A
2, 6, 8
146E-3101-2N00
24 VAC
100 ohm DIN
-100 to 1112°F
Low Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV G5PY -100 1112 A
2, 6, 8
146E-3101-2P00
24 VAC
100 ohm DIN
-73 to 600°C
Low Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV G5RY -073 0600 A
2, 6, 8
146E-3101-2P00
24 VAC
100 ohm DIN
-100 to 1112°F
Low Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV G5PY -100 1112 A
2, 6, 8
146E-3101-2S00
24 VAC
100 ohm DIN
-73 to 600°C
Low Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV G5RY -073 0600 A
2, 6, 8
146E-3101-2S00
24 VAC
100 ohm DIN
-100 to 1112°F
Low Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV G5PY -100 1112 A
2, 6, 8
146E-3101-3000
24 VAC
100 ohm DIN
-73 to 600°C
High Limit
Auto Reset
8A Relay
Integral
DIN Rail
LV G6RW -073 0600 A
6, 8
146E-3101-3000
24 VAC
100 ohm DIN
-100 to 1112°F
High Limit
Auto Reset
8A Relay
Integral
DIN Rail
LV G6PW -100 1112 A
6, 8
146E-3101-3N00
24 VAC
100 ohm DIN
-73 to 600°C
High Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV G5RW -073 0600 A
2, 6, 8
146E-3101-3N00
24 VAC
100 ohm DIN
-100 to 1112°F
High Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV G5PW -100 1112 A
2, 6, 8
146E-3101-3P00
24 VAC
100 ohm DIN
-73 to 600°C
High Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV G5RW -073 0600 A
2, 6, 8
146E-3101-3P00
24 VAC
100 ohm DIN
-100 to 1112°F
High Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV G5PW -100 1112 A
2, 6, 8
146E-3101-3S00
24 VAC
100 ohm DIN
-73 to 600°C
High Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV G5RW -073 0600 A
2, 6, 8
146E-3101-3S00
24 VAC
100 ohm DIN
-100 to 1112°F
High Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV G5PW -100 1112 A
2, 6, 8
146E-3101-4000
24 VAC
100 ohm DIN
-73 to 600°C
Low Limit
Auto Reset
8A Relay
Integral
DIN Rail
LV G6RY -073 0600 A
6, 8
Watlow Controls
3/30/2005