Series 146 – Watlow Series 146 Retrofit User Manual
Page 59
Series 146
Series 146
Line
Voltage
Input
Temp Range
Control
Mode
Action
Output
Set Point
Mounting
Retrofit control
See Notes
Below
146E-1K4F-3200
120 VAC
K t/c
32 to 150°F
High Limit
Auto Reset
10A Relay
Remote
DIN Rail
LV C5KW 0032 0150 A
2, 3, 6
146E-1K4F-4100
120 VAC
K t/c
32 to 150°F
Low Limit
Auto Reset
10A Relay
Integral
DIN Rail
LV C6KZ 0032 0150 A
3, 6
146E-1K4F-4200
120 VAC
K t/c
32 to 150°F
Low Limit
Auto Reset
10A Relay
Remote
DIN Rail
LV C5KZ 0032 0150 A
2, 3, 6
146E-1K5C-1100
120 VAC
K t/c
-17 to 315°C
High Limit
Manual Reset
10A Relay
Integral
DIN Rail
LV C6LU -017 0315 A
3, 6
146E-1K5C-1200
120 VAC
K t/c
-17 to 315°C
High Limit
Manual Reset
10A Relay
Remote
DIN Rail
LV C5LU -017 0315 A
2, 3, 6
146E-1K5C-2100
120 VAC
K t/c
-17 to 315°C
Low Limit
Manual Reset
10A Relay
Integral
DIN Rail
LV C6LY -017 0315 A
3, 6
146E-1K5C-2200
120 VAC
K t/c
-17 to 315°C
Low Limit
Manual Reset
10A Relay
Remote
DIN Rail
LV C5LY -017 0315 A
2, 3, 6
146E-1K5C-3100
120 VAC
K t/c
-17 to 315°C
High Limit
Auto Reset
10A Relay
Integral
DIN Rail
LV C6LW -017 0315 A
3, 6
146E-1K5C-3200
120 VAC
K t/c
-17 to 315°C
High Limit
Auto Reset
10A Relay
Remote
DIN Rail
LV C5LW -017 0315 A
2, 3, 6
146E-1K5C-4100
120 VAC
K t/c
-17 to 315°C
Low Limit
Auto Reset
10A Relay
Integral
DIN Rail
LV C6LZ -017 0315 A
3, 6
146E-1K5C-4200
120 VAC
K t/c
-17 to 315°C
Low Limit
Auto Reset
10A Relay
Remote
DIN Rail
LV C5LZ -017 0315 A
2, 3, 6
146E-1K5D-1100
120 VAC
K t/c
0 to 600°F
High Limit
Manual Reset
10A Relay
Integral
DIN Rail
LV C6KU 0000 0600 A
3, 6, 8
146E-1K5D-1100
120 VAC
K t/c
-17 to 315°C
High Limit
Manual Reset
10A Relay
Integral
DIN Rail
LV C6LU -017 0315 A
3, 6, 8
146E-1K5D-1200
120 VAC
K t/c
0 to 600°F
High Limit
Manual Reset
10A Relay
Remote
DIN Rail
LV C5KU 0000 0600 A
2, 3, 6, 8
146E-1K5D-1200
120 VAC
K t/c
-17 to 315°C
High Limit
Manual Reset
10A Relay
Remote
DIN Rail
LV C5LU -017 0315 A
2, 3, 6, 8
146E-1K5D-2100
120 VAC
K t/c
0 to 600°F
Low Limit
Manual Reset
10A Relay
Integral
DIN Rail
LV C6KY 0000 0600 A
3, 6, 8
146E-1K5D-2100
120 VAC
K t/c
-17 to 315°C
Low Limit
Manual Reset
10A Relay
Integral
DIN Rail
LV C6LY -017 0315 A
3, 6, 8
146E-1K5D-2200
120 VAC
K t/c
0 to 600°F
Low Limit
Manual Reset
10A Relay
Remote
DIN Rail
LV C5KY 0000 0600 A
2, 3, 6, 8
146E-1K5D-2200
120 VAC
K t/c
-17 to 315°C
Low Limit
Manual Reset
10A Relay
Remote
DIN Rail
LV C5LY -017 0315 A
2, 3, 6, 8
146E-1K5D-3100
120 VAC
K t/c
0 to 600°F
High Limit
Auto Reset
10A Relay
Integral
DIN Rail
LV C6KW 0000 0600 A
3, 6, 8
146E-1K5D-3100
120 VAC
K t/c
-17 to 315°C
High Limit
Auto Reset
10A Relay
Integral
DIN Rail
LV C6LW -017 0315 A
3, 6, 8
146E-1K5D-3200
120 VAC
K t/c
0 to 600°F
High Limit
Auto Reset
10A Relay
Remote
DIN Rail
LV C5KW 0000 0600 A
2, 3, 6, 8
146E-1K5D-3200
120 VAC
K t/c
-17 to 315°C
High Limit
Auto Reset
10A Relay
Remote
DIN Rail
LV C5LW -017 0315 A
2, 3, 6, 8
146E-1K5D-4100
120 VAC
K t/c
0 to 600°F
Low Limit
Auto Reset
10A Relay
Integral
DIN Rail
LV C6KZ 0000 0600 A
3, 6, 8
146E-1K5D-4100
120 VAC
K t/c
-17 to 315°C
Low Limit
Auto Reset
10A Relay
Integral
DIN Rail
LV C6LZ -017 0315 A
3, 6, 8
146E-1K5D-4200
120 VAC
K t/c
0 to 600°F
Low Limit
Auto Reset
10A Relay
Remote
DIN Rail
LV C5KZ 0000 0600 A
2, 3, 6, 8
146E-1K5D-4200
120 VAC
K t/c
-17 to 315°C
Low Limit
Auto Reset
10A Relay
Remote
DIN Rail
LV C5LZ -017 0315 A
2, 3, 6, 8
146E-1K5F-1100
120 VAC
K t/c
0 to 600°F
High Limit
Manual Reset
10A Relay
Integral
DIN Rail
LV C6KU 0000 0600 A
3, 6
146E-1K5F-1200
120 VAC
K t/c
0 to 600°F
High Limit
Manual Reset
10A Relay
Remote
DIN Rail
LV C5KU 0000 0600 A
2, 3, 6
146E-1K5F-2100
120 VAC
K t/c
0 to 600°F
Low Limit
Manual Reset
10A Relay
Integral
DIN Rail
LV C6KY 0000 0600 A
3, 6
146E-1K5F-2200
120 VAC
K t/c
0 to 600°F
Low Limit
Manual Reset
10A Relay
Remote
DIN Rail
LV C5KY 0000 0600 A
2, 3, 6
146E-1K5F-3100
120 VAC
K t/c
0 to 600°F
High Limit
Auto Reset
10A Relay
Integral
DIN Rail
LV C6KW 0000 0600 A
3, 6
146E-1K5F-3200
120 VAC
K t/c
0 to 600°F
High Limit
Auto Reset
10A Relay
Remote
DIN Rail
LV C5KW 0000 0600 A
2, 3, 6
146E-1K5F-4100
120 VAC
K t/c
0 to 600°F
Low Limit
Auto Reset
10A Relay
Integral
DIN Rail
LV C6KZ 0000 0600 A
3, 6
146E-1K5F-4200
120 VAC
K t/c
0 to 600°F
Low Limit
Auto Reset
10A Relay
Remote
DIN Rail
LV C5KZ 0000 0600 A
2, 3, 6
146E-1P1C-1100
120 VAC
100 ohm DIN
-73 to 600°C
High Limit
Manual Reset
10A Relay
Integral
DIN Rail
LV C6RU -073 0600 A
3, 6
146E-1P1C-1200
120 VAC
100 ohm DIN
-73 to 600°C
High Limit
Manual Reset
10A Relay
Remote
DIN Rail
LV C5RU -073 0600 A
2, 3, 6
146E-1P1C-2100
120 VAC
100 ohm DIN
-73 to 600°C
Low Limit
Manual Reset
10A Relay
Integral
DIN Rail
LV C6RY -073 0600 A
3, 6
146E-1P1C-2200
120 VAC
100 ohm DIN
-73 to 600°C
Low Limit
Manual Reset
10A Relay
Remote
DIN Rail
LV C5RY -073 0600 A
2, 3, 6
146E-1P1C-3100
120 VAC
100 ohm DIN
-73 to 600°C
High Limit
Auto Reset
10A Relay
Integral
DIN Rail
LV C6RW -073 0600 A
3, 6
146E-1P1C-3200
120 VAC
100 ohm DIN
-73 to 600°C
High Limit
Auto Reset
10A Relay
Remote
DIN Rail
LV C5RW -073 0600 A
2, 3, 6
Watlow Controls
3/30/2005
Page 54