Series 146 – Watlow Series 146 Retrofit User Manual
Page 111
Series 146
Series 146
Line
Voltage
Input
Temp Range
Control
Mode
Action
Output
Set Point
Mounting
Retrofit control
See Notes
Below
146E-3T1D-3100
24 VAC
T t/c
-200 to 350°C
High Limit
Auto Reset
10A Relay
Integral
DIN Rail
LV G6NW -200 0350 A
3, 6, 8
146E-3T1D-3200
24 VAC
T t/c
-328 to 662°F
High Limit
Auto Reset
10A Relay
Remote
DIN Rail
LV G5MW -328 0662 A
2, 3, 6, 8
146E-3T1D-3200
24 VAC
T t/c
-200 to 350°C
High Limit
Auto Reset
10A Relay
Remote
DIN Rail
LV G5NW -200 0350 A
2, 3, 6, 8
146E-3T1D-4100
24 VAC
T t/c
-328 to 662°F
Low Limit
Auto Reset
10A Relay
Integral
DIN Rail
LV G6MZ -328 0662 A
3, 6, 8
146E-3T1D-4100
24 VAC
T t/c
-200 to 350°C
Low Limit
Auto Reset
10A Relay
Integral
DIN Rail
LV G6NZ -200 0350 A
3, 6, 8
146E-3T1D-4200
24 VAC
T t/c
-328 to 662°F
Low Limit
Auto Reset
10A Relay
Remote
DIN Rail
LV G5MZ -328 0662 A
2, 3, 6, 8
146E-3T1D-4200
24 VAC
T t/c
-200 to 350°C
Low Limit
Auto Reset
10A Relay
Remote
DIN Rail
LV G5NZ -200 0350 A
2, 3, 6, 8
146E-3T1F-1100
24 VAC
T t/c
-328 to 662°F
High Limit
Manual Reset
10A Relay
Integral
DIN Rail
LV G6MU -328 0662 A
3, 6
146E-3T1F-1200
24 VAC
T t/c
-328 to 662°F
High Limit
Manual Reset
10A Relay
Remote
DIN Rail
LV G5MU -328 0662 A
2, 3, 6
146E-3T1F-2100
24 VAC
T t/c
-328 to 662°F
Low Limit
Manual Reset
10A Relay
Integral
DIN Rail
LV G6MY -328 0662 A
3, 6
146E-3T1F-2200
24 VAC
T t/c
-328 to 662°F
Low Limit
Manual Reset
10A Relay
Remote
DIN Rail
LV G5MY -328 0662 A
2, 3, 6
146E-3T1F-3100
24 VAC
T t/c
-328 to 662°F
High Limit
Auto Reset
10A Relay
Integral
DIN Rail
LV G6MW -328 0662 A
3, 6
146E-3T1F-3200
24 VAC
T t/c
-328 to 662°F
High Limit
Auto Reset
10A Relay
Remote
DIN Rail
LV G5MW -328 0662 A
2, 3, 6
146E-3T1F-4100
24 VAC
T t/c
-328 to 662°F
Low Limit
Auto Reset
10A Relay
Integral
DIN Rail
LV G6MZ -328 0662 A
3, 6
146E-3T1F-4200
24 VAC
T t/c
-328 to 662°F
Low Limit
Auto Reset
10A Relay
Remote
DIN Rail
LV G5MZ -328 0662 A
2, 3, 6
Note 1: Retrofit controller requires a substitution of a 100 Ohm DIN RTD sensor.
Note 2: Mounting and dimensions of retrofit controller are different. Verify that sufficient panel space and depth is available.
Note 3: Retrofit controller outputs are different. Add external interposing mechanical or solid state relay if applicable.
Note 4: Retrofit controller has a programmable, not fixed set point. Lock set point using controller's lockout parameter.
Note 5: For DIN rail mounting or sub-panel mounting, purchase DIN rail adapter p/n 0822-0586-P001 for 1/32 DIN or p/n 0822-0586-P002 for 1/16 DIN.
Note 6: Add a quencharc suppressor, Watlow p/n 0804-0147-0000, for inductive loads.
Note 7: Retrofit does not have equivalent action (as example, no manual reset)
Note 8: Retrofit controller does not have dual dial scale.
Note 9: Hardware lockout is not available on retrofit.
Note 10: Retrofit controller does not have user selectable line voltage.
Note 11: Retrofit does not support remote set point or retransmit. If wires are on these pins, select a different retrofit.
Note 12: Retrofit controller does not have user selectable control action.
Note 13: Solid state sensor required for humidity. See http://www.vaisala.com
Note 14: Retrofit controller does not have user selectable control mode.
Note 15: Use auxiliay event board A007-1732-F4B8
Note 16: Retrofit communications are different, consult specifications.
Note 17: Verify retrofit input range matches application.