beautypg.com

Series 146 – Watlow Series 146 Retrofit User Manual

Page 104

background image

Series 146

Series 146

Line

Voltage

Input

Temp Range

Control

Mode

Action

Output

Set Point

Mounting

Retrofit control

See Notes

Below

146E-3J3D-3200

24 VAC

J t/c

300 to 800°F

High Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV G5HW 0300 0800 A

2, 3, 6, 8

146E-3J3D-3200

24 VAC

J t/c

149 to 427°C

High Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV G5JW 0149 0427 A

2, 3, 6, 8

146E-3J3D-4100

24 VAC

J t/c

300 to 800°F

Low Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV G6HZ 0300 0800 A

3, 6, 8

146E-3J3D-4100

24 VAC

J t/c

149 to 427°C

Low Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV G6JZ 0149 0427 A

3, 6, 8

146E-3J3D-4200

24 VAC

J t/c

300 to 800°F

Low Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV G5HZ 0300 0800 A

2, 3, 6, 8

146E-3J3D-4200

24 VAC

J t/c

149 to 427°C

Low Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV G5JZ 0149 0427 A

2, 3, 6, 8

146E-3J3F-1100

24 VAC

J t/c

300 to 800°F

High Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV G6HU 0300 0800 A

3, 6

146E-3J3F-1200

24 VAC

J t/c

300 to 800°F

High Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV G5HU 0300 0800 A

2, 3, 6

146E-3J3F-2100

24 VAC

J t/c

300 to 800°F

Low Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV G6HY 0300 0800 A

3, 6

146E-3J3F-2200

24 VAC

J t/c

300 to 800°F

Low Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV G5HY 0300 0800 A

2, 3, 6

146E-3J3F-3100

24 VAC

J t/c

300 to 800°F

High Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV G6HW 0300 0800 A

3, 6

146E-3J3F-3200

24 VAC

J t/c

300 to 800°F

High Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV G5HW 0300 0800 A

2, 3, 6

146E-3J3F-4100

24 VAC

J t/c

300 to 800°F

Low Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV G6HZ 0300 0800 A

3, 6

146E-3J3F-4200

24 VAC

J t/c

300 to 800°F

Low Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV G5HZ 0300 0800 A

2, 3, 6

146E-3J4C-1100

24 VAC

J t/c

-18 to 93°C

High Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV G6JU -018 0093 A

3, 6

146E-3J4C-1200

24 VAC

J t/c

-18 to 93°C

High Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV G5JU -018 0093 A

2, 3, 6

146E-3J4C-2100

24 VAC

J t/c

-18 to 93°C

Low Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV G6JY -018 0093 A

3, 6

146E-3J4C-2200

24 VAC

J t/c

-18 to 93°C

Low Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV G5JY -018 0093 A

2, 3, 6

146E-3J4C-3100

24 VAC

J t/c

-18 to 93°C

High Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV G6JW -018 0093 A

3, 6

146E-3J4C-3200

24 VAC

J t/c

-18 to 93°C

High Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV G5JW -018 0093 A

2, 3, 6

146E-3J4C-4100

24 VAC

J t/c

-18 to 93°C

Low Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV G6JZ -018 0093 A

3, 6

146E-3J4C-4200

24 VAC

J t/c

-18 to 93°C

Low Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV G5JZ -018 0093 A

2, 3, 6

146E-3J4D-1100

24 VAC

J t/c

0 to 200°F

High Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV G6HU 0000 0200 A

3, 6, 8

146E-3J4D-1100

24 VAC

J t/c

-18 to 93°C

High Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV G6JU -018 0093 A

3, 6, 8

146E-3J4D-1200

24 VAC

J t/c

0 to 200°F

High Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV G5HU 0000 0200 A

2, 3, 6, 8

146E-3J4D-1200

24 VAC

J t/c

-18 to 93°C

High Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV G5JU -018 0093 A

2, 3, 6, 8

146E-3J4D-2100

24 VAC

J t/c

0 to 200°F

Low Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV G6HY 0000 0200 A

3, 6, 8

146E-3J4D-2100

24 VAC

J t/c

-18 to 93°C

Low Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV G6JY -018 0093 A

3, 6, 8

146E-3J4D-2200

24 VAC

J t/c

0 to 200°F

Low Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV G5HY 0000 0200 A

2, 3, 6, 8

146E-3J4D-2200

24 VAC

J t/c

-18 to 93°C

Low Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV G5JY -018 0093 A

2, 3, 6, 8

146E-3J4D-3100

24 VAC

J t/c

0 to 200°F

High Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV G6HW 0000 0200 A

3, 6, 8

146E-3J4D-3100

24 VAC

J t/c

-18 to 93°C

High Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV G6JW -018 0093 A

3, 6, 8

146E-3J4D-3200

24 VAC

J t/c

0 to 200°F

High Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV G5HW 0000 0200 A

2, 3, 6, 8

146E-3J4D-3200

24 VAC

J t/c

-18 to 93°C

High Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV G5JW -018 0093 A

2, 3, 6, 8

146E-3J4D-4100

24 VAC

J t/c

0 to 200°F

Low Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV G6HZ 0000 0200 A

3, 6, 8

146E-3J4D-4100

24 VAC

J t/c

-18 to 93°C

Low Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV G6JZ -018 0093 A

3, 6, 8

146E-3J4D-4200

24 VAC

J t/c

0 to 200°F

Low Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV G5HZ 0000 0200 A

2, 3, 6, 8

146E-3J4D-4200

24 VAC

J t/c

-18 to 93°C

Low Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV G5JZ -018 0093 A

2, 3, 6, 8

146E-3J4F-1100

24 VAC

J t/c

0 to 200°F

High Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV G6HU 0000 0200 A

3, 6

146E-3J4F-1200

24 VAC

J t/c

0 to 200°F

High Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV G5HU 0000 0200 A

2, 3, 6

146E-3J4F-2100

24 VAC

J t/c

0 to 200°F

Low Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV G6HY 0000 0200 A

3, 6

Watlow Controls

3/30/2005