Series 146 – Watlow Series 146 Retrofit User Manual
Page 77
Series 146
Series 146
Line
Voltage
Input
Temp Range
Control
Mode
Action
Output
Set Point
Mounting
Retrofit control
See Notes
Below
146E-2E1F-4200
230 VAC
E t/c
32 to 1470°F
Low Limit
Auto Reset
10A Relay
Remote
DIN Rail
LV E5SZ 0032 1470 A
2, 3, 6
146E-2J1C-1100
230 VAC
J t/c
0 to 315°C
High Limit
Manual Reset
10A Relay
Integral
DIN Rail
LV E6JU 0000 0315 A
3, 6
146E-2J1C-1200
230 VAC
J t/c
0 to 315°C
High Limit
Manual Reset
10A Relay
Remote
DIN Rail
LV E5JU 0000 0315 A
2, 3, 6
146E-2J1C-2100
230 VAC
J t/c
0 to 315°C
Low Limit
Manual Reset
10A Relay
Integral
DIN Rail
LV E6JY 0000 0315 A
3, 6
146E-2J1C-2200
230 VAC
J t/c
0 to 315°C
Low Limit
Manual Reset
10A Relay
Remote
DIN Rail
LV E5JY 0000 0315 A
2, 3, 6
146E-2J1C-3100
230 VAC
J t/c
0 to 315°C
High Limit
Auto Reset
10A Relay
Integral
DIN Rail
LV E6JW 0000 0315 A
3, 6
146E-2J1C-3200
230 VAC
J t/c
0 to 315°C
High Limit
Auto Reset
10A Relay
Remote
DIN Rail
LV E5JW 0000 0315 A
2, 3, 6
146E-2J1C-4100
230 VAC
J t/c
0 to 315°C
Low Limit
Auto Reset
10A Relay
Integral
DIN Rail
LV E6JZ 0000 0315 A
3, 6
146E-2J1C-4200
230 VAC
J t/c
0 to 315°C
Low Limit
Auto Reset
10A Relay
Remote
DIN Rail
LV E5JZ 0000 0315 A
2, 3, 6
146E-2J1D-1100
230 VAC
J t/c
32 to 600°F
High Limit
Manual Reset
10A Relay
Integral
DIN Rail
LV E6HU 0032 0600 A
3, 6, 8
146E-2J1D-1100
230 VAC
J t/c
0 to 315°C
High Limit
Manual Reset
10A Relay
Integral
DIN Rail
LV E6JU 0000 0315 A
3, 6, 8
146E-2J1D-1200
230 VAC
J t/c
32 to 600°F
High Limit
Manual Reset
10A Relay
Remote
DIN Rail
LV E5HU 0032 0600 A
2, 3, 6, 8
146E-2J1D-1200
230 VAC
J t/c
0 to 315°C
High Limit
Manual Reset
10A Relay
Remote
DIN Rail
LV E5JU 0000 0315 A
2, 3, 6, 8
146E-2J1D-2100
230 VAC
J t/c
32 to 600°F
Low Limit
Manual Reset
10A Relay
Integral
DIN Rail
LV E6HY 0032 0600 A
3, 6, 8
146E-2J1D-2100
230 VAC
J t/c
0 to 315°C
Low Limit
Manual Reset
10A Relay
Integral
DIN Rail
LV E6JY 0000 0315 A
3, 6, 8
146E-2J1D-2200
230 VAC
J t/c
32 to 600°F
Low Limit
Manual Reset
10A Relay
Remote
DIN Rail
LV E5HY 0032 0600 A
2, 3, 6, 8
146E-2J1D-2200
230 VAC
J t/c
0 to 315°C
Low Limit
Manual Reset
10A Relay
Remote
DIN Rail
LV E5JY 0000 0315 A
2, 3, 6, 8
146E-2J1D-3100
230 VAC
J t/c
32 to 600°F
High Limit
Auto Reset
10A Relay
Integral
DIN Rail
LV E6HW 0032 0600 A
3, 6, 8
146E-2J1D-3100
230 VAC
J t/c
0 to 315°C
High Limit
Auto Reset
10A Relay
Integral
DIN Rail
LV E6JW 0000 0315 A
3, 6, 8
146E-2J1D-3200
230 VAC
J t/c
32 to 600°F
High Limit
Auto Reset
10A Relay
Remote
DIN Rail
LV E5HW 0032 0600 A
2, 3, 6, 8
146E-2J1D-3200
230 VAC
J t/c
0 to 315°C
High Limit
Auto Reset
10A Relay
Remote
DIN Rail
LV E5JW 0000 0315 A
2, 3, 6, 8
146E-2J1D-4100
230 VAC
J t/c
32 to 600°F
Low Limit
Auto Reset
10A Relay
Integral
DIN Rail
LV E6HZ 0032 0600 A
3, 6, 8
146E-2J1D-4100
230 VAC
J t/c
0 to 315°C
Low Limit
Auto Reset
10A Relay
Integral
DIN Rail
LV E6JZ 0000 0315 A
3, 6, 8
146E-2J1D-4200
230 VAC
J t/c
32 to 600°F
Low Limit
Auto Reset
10A Relay
Remote
DIN Rail
LV E5HZ 0032 0600 A
2, 3, 6, 8
146E-2J1D-4200
230 VAC
J t/c
0 to 315°C
Low Limit
Auto Reset
10A Relay
Remote
DIN Rail
LV E5JZ 0000 0315 A
2, 3, 6, 8
146E-2J1F-1100
230 VAC
J t/c
32 to 600°F
High Limit
Manual Reset
10A Relay
Integral
DIN Rail
LV E6HU 0032 0600 A
3, 6
146E-2J1F-1200
230 VAC
J t/c
32 to 600°F
High Limit
Manual Reset
10A Relay
Remote
DIN Rail
LV E5HU 0032 0600 A
2, 3, 6
146E-2J1F-2100
230 VAC
J t/c
32 to 600°F
Low Limit
Manual Reset
10A Relay
Integral
DIN Rail
LV E6HY 0032 0600 A
3, 6
146E-2J1F-2200
230 VAC
J t/c
32 to 600°F
Low Limit
Manual Reset
10A Relay
Remote
DIN Rail
LV E5HY 0032 0600 A
2, 3, 6
146E-2J1F-3100
230 VAC
J t/c
32 to 600°F
High Limit
Auto Reset
10A Relay
Integral
DIN Rail
LV E6HW 0032 0600 A
3, 6
146E-2J1F-3200
230 VAC
J t/c
32 to 600°F
High Limit
Auto Reset
10A Relay
Remote
DIN Rail
LV E5HW 0032 0600 A
2, 3, 6
146E-2J1F-4100
230 VAC
J t/c
32 to 600°F
Low Limit
Auto Reset
10A Relay
Integral
DIN Rail
LV E6HZ 0032 0600 A
3, 6
146E-2J1F-4200
230 VAC
J t/c
32 to 600°F
Low Limit
Auto Reset
10A Relay
Remote
DIN Rail
LV E5HZ 0032 0600 A
2, 3, 6
146E-2J2C-1100
230 VAC
J t/c
0 to 750°C
High Limit
Manual Reset
10A Relay
Integral
DIN Rail
LV E6JU 0000 0750 A
3, 6
146E-2J2C-1200
230 VAC
J t/c
0 to 750°C
High Limit
Manual Reset
10A Relay
Remote
DIN Rail
LV E5JU 0000 0750 A
2, 3, 6
146E-2J2C-2100
230 VAC
J t/c
0 to 750°C
Low Limit
Manual Reset
10A Relay
Integral
DIN Rail
LV E6JY 0000 0750 A
3, 6
146E-2J2C-2200
230 VAC
J t/c
0 to 750°C
Low Limit
Manual Reset
10A Relay
Remote
DIN Rail
LV E5JY 0000 0750 A
2, 3, 6
146E-2J2C-3100
230 VAC
J t/c
0 to 750°C
High Limit
Auto Reset
10A Relay
Integral
DIN Rail
LV E6JW 0000 0750 A
3, 6
146E-2J2C-3200
230 VAC
J t/c
0 to 750°C
High Limit
Auto Reset
10A Relay
Remote
DIN Rail
LV E5JW 0000 0750 A
2, 3, 6
146E-2J2C-4100
230 VAC
J t/c
0 to 750°C
Low Limit
Auto Reset
10A Relay
Integral
DIN Rail
LV E6JZ 0000 0750 A
3, 6
146E-2J2C-4200
230 VAC
J t/c
0 to 750°C
Low Limit
Auto Reset
10A Relay
Remote
DIN Rail
LV E5JZ 0000 0750 A
2, 3, 6
Watlow Controls
3/30/2005
Page 72