Series 146 – Watlow Series 146 Retrofit User Manual
Page 65

Series 146
Series 146
Line
Voltage
Input
Temp Range
Control
Mode
Action
Output
Set Point
Mounting
Retrofit control
See Notes
Below
146E-2112-2000
230 VAC
100 ohm DIN
482°F
Low Limit
Manual Reset
8A Relay
Fixed
DIN Rail
LF E6PY 0482 AAAA A
6, 8
146E-2112-3000
230 VAC
100 ohm DIN
250°C
High Limit
Auto Reset
8A Relay
Fixed
DIN Rail
LF E6RW 0250 AAAA A
6, 8
146E-2112-3000
230 VAC
100 ohm DIN
482°F
High Limit
Auto Reset
8A Relay
Fixed
DIN Rail
LF E6PW 0482 AAAA A
6, 8
146E-2112-4000
230 VAC
100 ohm DIN
250°C
Low Limit
Auto Reset
8A Relay
Fixed
DIN Rail
LF E6RZ 0250 AAAA A
6, 8
146E-2112-4000
230 VAC
100 ohm DIN
482°F
Low Limit
Auto Reset
8A Relay
Fixed
DIN Rail
LF E6PZ 0482 AAAA A
6, 8
146E-2601-1000
230 VAC
J t/c
32 to 600°F
High Limit
Manual Reset
8A Relay
Integral
DIN Rail
LV E6HU 0032 0600 A
6, 8
146E-2601-1000
230 VAC
J t/c
0 to 315°C
High Limit
Manual Reset
8A Relay
Integral
DIN Rail
LV E6JU 0000 0315 A
6, 8
146E-2601-1N00
230 VAC
J t/c
32 to 600°F
High Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV E5HU 0032 0600 A
2, 6, 8
146E-2601-1N00
230 VAC
J t/c
0 to 315°C
High Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV E5JU 0000 0315 A
2, 6, 8
146E-2601-1P00
230 VAC
J t/c
32 to 600°F
High Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV E5HU 0032 0600 A
2, 6, 8
146E-2601-1P00
230 VAC
J t/c
0 to 315°C
High Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV E5JU 0000 0315 A
2, 6, 8
146E-2601-1S00
230 VAC
J t/c
32 to 600°F
High Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV E5HU 0032 0600 A
2, 6, 8
146E-2601-1S00
230 VAC
J t/c
0 to 315°C
High Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV E5JU 0000 0315 A
2, 6, 8
146E-2601-2000
230 VAC
J t/c
32 to 600°F
Low Limit
Manual Reset
8A Relay
Integral
DIN Rail
LV E6HY 0032 0600 A
6, 8
146E-2601-2000
230 VAC
J t/c
0 to 315°C
Low Limit
Manual Reset
8A Relay
Integral
DIN Rail
LV E6JY 0000 0315 A
6, 8
146E-2601-2N00
230 VAC
J t/c
32 to 600°F
Low Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV E5HY 0032 0600 A
2, 6, 8
146E-2601-2N00
230 VAC
J t/c
0 to 315°C
Low Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV E5JY 0000 0315 A
2, 6, 8
146E-2601-2P00
230 VAC
J t/c
32 to 600°F
Low Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV E5HY 0032 0600 A
2, 6, 8
146E-2601-2P00
230 VAC
J t/c
0 to 315°C
Low Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV E5JY 0000 0315 A
2, 6, 8
146E-2601-2S00
230 VAC
J t/c
32 to 600°F
Low Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV E5HY 0032 0600 A
2, 6, 8
146E-2601-2S00
230 VAC
J t/c
0 to 315°C
Low Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV E5JY 0000 0315 A
2, 6, 8
146E-2601-3000
230 VAC
J t/c
32 to 600°F
High Limit
Auto Reset
8A Relay
Integral
DIN Rail
LV E6HW 0032 0600 A
6, 8
146E-2601-3000
230 VAC
J t/c
0 to 315°C
High Limit
Auto Reset
8A Relay
Integral
DIN Rail
LV E6JW 0000 0315 A
6, 8
146E-2601-3N00
230 VAC
J t/c
32 to 600°F
High Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV E5HW 0032 0600 A
2, 6, 8
146E-2601-3N00
230 VAC
J t/c
0 to 315°C
High Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV E5JW 0000 0315 A
2, 6, 8
146E-2601-3P00
230 VAC
J t/c
32 to 600°F
High Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV E5HW 0032 0600 A
2, 6, 8
146E-2601-3P00
230 VAC
J t/c
0 to 315°C
High Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV E5JW 0000 0315 A
2, 6, 8
146E-2601-3S00
230 VAC
J t/c
32 to 600°F
High Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV E5HW 0032 0600 A
2, 6, 8
146E-2601-3S00
230 VAC
J t/c
0 to 315°C
High Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV E5JW 0000 0315 A
2, 6, 8
146E-2601-4000
230 VAC
J t/c
32 to 600°F
Low Limit
Auto Reset
8A Relay
Integral
DIN Rail
LV E6HZ 0032 0600 A
6, 8
146E-2601-4000
230 VAC
J t/c
0 to 315°C
Low Limit
Auto Reset
8A Relay
Integral
DIN Rail
LV E6JZ 0000 0315 A
6, 8
146E-2601-4N00
230 VAC
J t/c
32 to 600°F
Low Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV E5HZ 0032 0600 A
2, 6, 8
146E-2601-4N00
230 VAC
J t/c
0 to 315°C
Low Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV E5JZ 0000 0315 A
2, 6, 8
146E-2601-4P00
230 VAC
J t/c
32 to 600°F
Low Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV E5HZ 0032 0600 A
2, 6, 8
146E-2601-4P00
230 VAC
J t/c
0 to 315°C
Low Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV E5JZ 0000 0315 A
2, 6, 8
146E-2601-4S00
230 VAC
J t/c
32 to 600°F
Low Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV E5HZ 0032 0600 A
2, 6, 8
146E-2601-4S00
230 VAC
J t/c
0 to 315°C
Low Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV E5JZ 0000 0315 A
2, 6, 8
146E-2602-1000
230 VAC
J t/c
32 to 1382°F
High Limit
Manual Reset
8A Relay
Integral
DIN Rail
LV E6HU 0032 1382 A
6, 8
146E-2602-1000
230 VAC
J t/c
0 to 750°C
High Limit
Manual Reset
8A Relay
Integral
DIN Rail
LV E6JU 0000 0750 A
6, 8
146E-2602-1N00
230 VAC
J t/c
32 to 1382°F
High Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV E5HU 0032 1382 A
2, 6, 8
146E-2602-1N00
230 VAC
J t/c
0 to 750°C
High Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV E5JU 0000 0750 A
2, 6, 8
Watlow Controls
3/30/2005
Page 60