Series 146 source.pdf, Series 146 – Watlow Series 146 Retrofit User Manual
Page 6
![background image](/manuals/359174/6/background.png)
Series 146
Series 146
Line
Voltage
Input
Temp Range
Control
Mode
Action
Output
Set Point
Mounting
Retrofit control
See Notes
Below
146D-1E1C-1100
120 VAC
E t/c
0 to 799°C
High Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV C6TU 0000 0799 A
6
146D-1E1C-1200
120 VAC
E t/c
0 to 799°C
High Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV C5TU 0000 0799 A
2, 6
146D-1E1C-2100
120 VAC
E t/c
0 to 799°C
Low Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV C6TY 0000 0799 A
6
146D-1E1C-2200
120 VAC
E t/c
0 to 799°C
Low Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV C5TY 0000 0799 A
2, 6
146D-1E1C-3100
120 VAC
E t/c
0 to 799°C
High Limit
Auto Reset
3A Relay
Integral
DIN Rail
LV C6TW 0000 0799 A
6
146D-1E1C-3200
120 VAC
E t/c
0 to 799°C
High Limit
Auto Reset
3A Relay
Remote
DIN Rail
LV C5TW 0000 0799 A
2, 6
146D-1E1C-4100
120 VAC
E t/c
0 to 799°C
Low Limit
Auto Reset
3A Relay
Integral
DIN Rail
LV C6TZ 0000 0799 A
6
146D-1E1C-4200
120 VAC
E t/c
0 to 799°C
Low Limit
Auto Reset
3A Relay
Remote
DIN Rail
LV C5TZ 0000 0799 A
2, 6
146D-1E1D-1100
120 VAC
E t/c
32 to 1470°F
High Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV C6SU 0032 1470 A
6, 8
146D-1E1D-1100
120 VAC
E t/c
0 to 799°C
High Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV C6TU 0000 0799 A
6, 8
146D-1E1D-1200
120 VAC
E t/c
32 to 1470°F
High Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV C5SU 0032 1470 A
2, 6, 8
146D-1E1D-1200
120 VAC
E t/c
0 to 799°C
High Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV C5TU 0000 0799 A
2, 6, 8
146D-1E1D-2100
120 VAC
E t/c
32 to 1470°F
Low Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV C6SY 0032 1470 A
6, 8
146D-1E1D-2100
120 VAC
E t/c
0 to 799°C
Low Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV C6TY 0000 0799 A
6, 8
146D-1E1D-2200
120 VAC
E t/c
32 to 1470°F
Low Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV C5SY 0032 1470 A
2, 6, 8
146D-1E1D-2200
120 VAC
E t/c
0 to 799°C
Low Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV C5TY 0000 0799 A
2, 6, 8
146D-1E1D-3100
120 VAC
E t/c
32 to 1470°F
High Limit
Auto Reset
3A Relay
Integral
DIN Rail
LV C6SW 0032 1470 A
6, 8
146D-1E1D-3100
120 VAC
E t/c
0 to 799°C
High Limit
Auto Reset
3A Relay
Integral
DIN Rail
LV C6TW 0000 0799 A
6, 8
146D-1E1D-3200
120 VAC
E t/c
32 to 1470°F
High Limit
Auto Reset
3A Relay
Remote
DIN Rail
LV C5SW 0032 1470 A
2, 6, 8
146D-1E1D-3200
120 VAC
E t/c
0 to 799°C
High Limit
Auto Reset
3A Relay
Remote
DIN Rail
LV C5TW 0000 0799 A
2, 6, 8
146D-1E1D-4100
120 VAC
E t/c
32 to 1470°F
Low Limit
Auto Reset
3A Relay
Integral
DIN Rail
LV C6SZ 0032 1470 A
6, 8
146D-1E1D-4100
120 VAC
E t/c
0 to 799°C
Low Limit
Auto Reset
3A Relay
Integral
DIN Rail
LV C6TZ 0000 0799 A
6, 8
146D-1E1D-4200
120 VAC
E t/c
32 to 1470°F
Low Limit
Auto Reset
3A Relay
Remote
DIN Rail
LV C5SZ 0032 1470 A
2, 6, 8
146D-1E1D-4200
120 VAC
E t/c
0 to 799°C
Low Limit
Auto Reset
3A Relay
Remote
DIN Rail
LV C5TZ 0000 0799 A
2, 6, 8
146D-1E1F-1100
120 VAC
E t/c
32 to 1470°F
High Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV C6SU 0032 1470 A
6
146D-1E1F-1200
120 VAC
E t/c
32 to 1470°F
High Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV C5SU 0032 1470 A
2, 6
146D-1E1F-2100
120 VAC
E t/c
32 to 1470°F
Low Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV C6SY 0032 1470 A
6
146D-1E1F-2200
120 VAC
E t/c
32 to 1470°F
Low Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV C5SY 0032 1470 A
2, 6
146D-1E1F-3100
120 VAC
E t/c
32 to 1470°F
High Limit
Auto Reset
3A Relay
Integral
DIN Rail
LV C6SW 0032 1470 A
6
146D-1E1F-3200
120 VAC
E t/c
32 to 1470°F
High Limit
Auto Reset
3A Relay
Remote
DIN Rail
LV C5SW 0032 1470 A
2, 6
146D-1E1F-4100
120 VAC
E t/c
32 to 1470°F
Low Limit
Auto Reset
3A Relay
Integral
DIN Rail
LV C6SZ 0032 1470 A
6
146D-1E1F-4200
120 VAC
E t/c
32 to 1470°F
Low Limit
Auto Reset
3A Relay
Remote
DIN Rail
LV C5SZ 0032 1470 A
2, 6
146D-1J1C-1100
120 VAC
J t/c
0 to 315°C
High Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV C6JU 0000 0315 A
6
146D-1J1C-1200
120 VAC
J t/c
0 to 315°C
High Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV C5JU 0000 0315 A
2, 6
146D-1J1C-2100
120 VAC
J t/c
0 to 315°C
Low Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV C6JY 0000 0315 A
6
146D-1J1C-2200
120 VAC
J t/c
0 to 315°C
Low Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV C5JY 0000 0315 A
2, 6
146D-1J1C-3100
120 VAC
J t/c
0 to 315°C
High Limit
Auto Reset
3A Relay
Integral
DIN Rail
LV C6JW 0000 0315 A
6
146D-1J1C-3200
120 VAC
J t/c
0 to 315°C
High Limit
Auto Reset
3A Relay
Remote
DIN Rail
LV C5JW 0000 0315 A
2, 6
146D-1J1C-4100
120 VAC
J t/c
0 to 315°C
Low Limit
Auto Reset
3A Relay
Integral
DIN Rail
LV C6JZ 0000 0315 A
6
146D-1J1C-4200
120 VAC
J t/c
0 to 315°C
Low Limit
Auto Reset
3A Relay
Remote
DIN Rail
LV C5JZ 0000 0315 A
2, 6
146D-1J1D-1100
120 VAC
J t/c
32 to 600°F
High Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV C6HU 0032 0600 A
6, 8
Watlow Controls
3/30/2005
Page 1