Series 146

Line

Voltage

Input

Temp Range

Control

Mode

Action

Output

Set Point

Mounting

Retrofit control

See Notes

Below

146E-1K3D-4100

120 VAC

K t/c

32 to 1112°F

Low Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV C6KZ 0032 1112 A

3, 6, 8

146E-1K3D-4100

120 VAC

K t/c

0 to 600°C

Low Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV C6LZ 0000 0600 A

3, 6, 8

146E-1K3D-4200

120 VAC

K t/c

32 to 1112°F

Low Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV C5KZ0032 1112 A

2, 3, 6, 8

146E-1K3D-4200

120 VAC

K t/c

0 to 600°C

Low Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV C5LZ 0000 0600 A

2, 3, 6, 8

146E-1K3F-1100

120 VAC

K t/c

32 to 1112°F

High Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV C6KU 0032 1112 A

3, 6

146E-1K3F-1200

120 VAC

K t/c

32 to 1112°F

High Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV C5KU 0032 1112 A

2, 3, 6

146E-1K3F-2100

120 VAC

K t/c

32 to 1112°F

Low Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV C6KY0032 1112 A

3, 6

146E-1K3F-2200

120 VAC

K t/c

32 to 1112°F

Low Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV C5KY 0032 1112 A

2, 3, 6

146E-1K3F-3100

120 VAC

K t/c

32 to 1112°F

High Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV C6KW 0032 1112 A

3, 6

146E-1K3F-3200

120 VAC

K t/c

32 to 1112°F

High Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV C5KW 0032 1112 A

2, 3, 6

146E-1K3F-4100

120 VAC

K t/c

32 to 1112°F

Low Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV C6KZ 0032 1112 A

3, 6

146E-1K3F-4200

120 VAC

K t/c

32 to 1112°F

Low Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV C5KZ0032 1112 A

2, 3, 6

146E-1K4C-1100

120 VAC

K t/c

0 to 66°C

High Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV C6LU 0000 0066 A

3, 6

146E-1K4C-1200

120 VAC

K t/c

0 to 66°C

High Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV C5LU 0000 0066 A

2, 3, 6

146E-1K4C-2100

120 VAC

K t/c

0 to 66°C

Low Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV C6LY 0000 0066 A

3, 6

146E-1K4C-2200

120 VAC

K t/c

0 to 66°C

Low Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV C5LY 0000 0066 A

2, 3, 6

146E-1K4C-3100

120 VAC

K t/c

0 to 66°C

High Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV C6LW 0000 0066 A

3, 6

146E-1K4C-3200

120 VAC

K t/c

0 to 66°C

High Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV C5LW 0000 0066 A

2, 3, 6

146E-1K4C-4100

120 VAC

K t/c

0 to 66°C

Low Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV C6LZ 0000 0066 A

3, 6

146E-1K4C-4200

120 VAC

K t/c

0 to 66°C

Low Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV C5LZ 0000 0066 A

2, 3, 6

146E-1K4D-1100

120 VAC

K t/c

32 to 150°F

High Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV C6KU 0032 0150 A

3, 6, 8

146E-1K4D-1100

120 VAC

K t/c

0 to 66°C

High Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV C6LU 0000 0066 A

3, 6, 8

146E-1K4D-1200

120 VAC

K t/c

32 to 150°F

High Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV C5KU 0032 0150 A

2, 3, 6, 8

146E-1K4D-1200

120 VAC

K t/c

0 to 66°C

High Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV C5LU 0000 0066 A

2, 3, 6, 8

146E-1K4D-2100

120 VAC

K t/c

32 to 150°F

Low Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV C6KY 0032 0150 A

3, 6, 8

146E-1K4D-2100

120 VAC

K t/c

0 to 66°C

Low Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV C6LY 0000 0066 A

3, 6, 8

146E-1K4D-2200

120 VAC

K t/c

32 to 150°F

Low Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV C5KY 0032 0150 A

2, 3, 6, 8

146E-1K4D-2200

120 VAC

K t/c

0 to 66°C

Low Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV C5LY 0000 0066 A

2, 3, 6, 8

146E-1K4D-3100

120 VAC

K t/c

32 to 150°F

High Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV C6KW 0032 0150 A

3, 6, 8

146E-1K4D-3100

120 VAC

K t/c

0 to 66°C

High Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV C6LW 0000 0066 A

3, 6, 8

146E-1K4D-3200

120 VAC

K t/c

32 to 150°F

High Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV C5KW 0032 0150 A

2, 3, 6, 8

146E-1K4D-3200

120 VAC

K t/c

0 to 66°C

High Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV C5LW 0000 0066 A

2, 3, 6, 8

146E-1K4D-4100

120 VAC

K t/c

32 to 150°F

Low Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV C6KZ 0032 0150 A

3, 6, 8

146E-1K4D-4100

120 VAC

K t/c

0 to 66°C

Low Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV C6LZ 0000 0066 A

3, 6, 8

146E-1K4D-4200

120 VAC

K t/c

32 to 150°F

Low Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV C5KZ 0032 0150 A

2, 3, 6, 8

146E-1K4D-4200

120 VAC

K t/c

0 to 66°C

Low Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV C5LZ 0000 0066 A

2, 3, 6, 8

146E-1K4F-1100

120 VAC

K t/c

32 to 150°F

High Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV C6KU 0032 0150 A

3, 6

146E-1K4F-1200

120 VAC

K t/c

32 to 150°F

High Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV C5KU 0032 0150 A

2, 3, 6

146E-1K4F-2100

120 VAC

K t/c

32 to 150°F

Low Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV C6KY 0032 0150 A

3, 6

146E-1K4F-2200

120 VAC

K t/c

32 to 150°F

Low Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV C5KY 0032 0150 A

2, 3, 6

146E-1K4F-3100

120 VAC

K t/c

32 to 150°F

High Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV C6KW 0032 0150 A

3, 6

Watlow Controls

3/30/2005