Series 146
Series 146
Line
Voltage
Input
Temp Range
Control
Mode
Action
Output
Set Point
Mounting
Retrofit control
See Notes
Below
146D-2K1C-4200
230 VAC
K t/c
0 to 1250°C
Low Limit
Auto Reset
3A Relay
Remote
DIN Rail
LV E5LZ 0000 1250 A
2, 6
146D-2K1D-1100
230 VAC
K t/c
32 to 2282°F
High Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV E6KU 0032 2282 A
6, 8
146D-2K1D-1100
230 VAC
K t/c
0 to 1250°C
High Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV E6LU 0000 1250 A
6, 8
146D-2K1D-1200
230 VAC
K t/c
32 to 2282°F
High Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV E5KU 0032 2282 A
2, 6, 8
146D-2K1D-1200
230 VAC
K t/c
0 to 1250°C
High Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV E5LU 0000 1250 A
2, 6, 8
146D-2K1D-2100
230 VAC
K t/c
32 to 2282°F
Low Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV E6KY 0032 2282 A
6, 8
146D-2K1D-2100
230 VAC
K t/c
0 to 1250°C
Low Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV E6LY 0000 1250 A
6, 8
146D-2K1D-2200
230 VAC
K t/c
32 to 2282°F
Low Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV E5KY 0032 2282 A
2, 6, 8
146D-2K1D-2200
230 VAC
K t/c
0 to 1250°C
Low Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV E5LY 0000 1250 A
2, 6, 8
146D-2K1D-3100
230 VAC
K t/c
32 to 2282°F
High Limit
Auto Reset
3A Relay
Integral
DIN Rail
LV E6KW 0032 2282 A
6, 8
146D-2K1D-3100
230 VAC
K t/c
0 to 1250°C
High Limit
Auto Reset
3A Relay
Integral
DIN Rail
LV E6LW 0000 1250 A
6, 8
146D-2K1D-3200
230 VAC
K t/c
32 to 2282°F
High Limit
Auto Reset
3A Relay
Remote
DIN Rail
LV E5KW 0032 2282 A
2, 6, 8
146D-2K1D-3200
230 VAC
K t/c
0 to 1250°C
High Limit
Auto Reset
3A Relay
Remote
DIN Rail
LV E5LW 0000 1250 A
2, 6, 8
146D-2K1D-4100
230 VAC
K t/c
32 to 2282°F
Low Limit
Auto Reset
3A Relay
Integral
DIN Rail
LV E6KZ 0032 2282 A
6, 8
146D-2K1D-4100
230 VAC
K t/c
0 to 1250°C
Low Limit
Auto Reset
3A Relay
Integral
DIN Rail
LV E6LZ 0000 1250 A
6, 8
146D-2K1D-4200
230 VAC
K t/c
32 to 2282°F
Low Limit
Auto Reset
3A Relay
Remote
DIN Rail
LV E5KZ 0032 2282 A
2, 6, 8
146D-2K1D-4200
230 VAC
K t/c
0 to 1250°C
Low Limit
Auto Reset
3A Relay
Remote
DIN Rail
LV E5LZ 0000 1250 A
2, 6, 8
146D-2K1F-1100
230 VAC
K t/c
32 to 2282°F
High Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV E6KU 0032 2282 A
6
146D-2K1F-1200
230 VAC
K t/c
32 to 2282°F
High Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV E5KU 0032 2282 A
2, 6
146D-2K1F-2100
230 VAC
K t/c
32 to 2282°F
Low Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV E6KY 0032 2282 A
6
146D-2K1F-2200
230 VAC
K t/c
32 to 2282°F
Low Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV E5KY 0032 2282 A
2, 6
146D-2K1F-3100
230 VAC
K t/c
32 to 2282°F
High Limit
Auto Reset
3A Relay
Integral
DIN Rail
LV E6KW 0032 2282 A
6
146D-2K1F-3200
230 VAC
K t/c
32 to 2282°F
High Limit
Auto Reset
3A Relay
Remote
DIN Rail
LV E5KW 0032 2282 A
2, 6
146D-2K1F-4100
230 VAC
K t/c
32 to 2282°F
Low Limit
Auto Reset
3A Relay
Integral
DIN Rail
LV E6KZ 0032 2282 A
6
146D-2K1F-4200
230 VAC
K t/c
32 to 2282°F
Low Limit
Auto Reset
3A Relay
Remote
DIN Rail
LV E5KZ 0032 2282 A
2, 6
146D-2K2C-1100
230 VAC
K t/c
16 to 149°C
High Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV E6LU 0016 0149 A
6
146D-2K2C-1200
230 VAC
K t/c
16 to 149°C
High Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV E5LU 0016 0149 A
2, 6
146D-2K2C-2100
230 VAC
K t/c
16 to 149°C
Low Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV E6LY 0016 0149 A
6
146D-2K2C-2200
230 VAC
K t/c
16 to 149°C
Low Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV E5LY 0016 0149 A
2, 6
146D-2K2C-3100
230 VAC
K t/c
16 to 149°C
High Limit
Auto Reset
3A Relay
Integral
DIN Rail
LV E6LW 0016 0149 A
6
146D-2K2C-3200
230 VAC
K t/c
16 to 149°C
High Limit
Auto Reset
3A Relay
Remote
DIN Rail
LV E5LW 0016 0149 A
2, 6
146D-2K2C-4100
230 VAC
K t/c
16 to 149°C
Low Limit
Auto Reset
3A Relay
Integral
DIN Rail
LV E6LZ 0016 0149 A
6
146D-2K2C-4200
230 VAC
K t/c
16 to 149°C
Low Limit
Auto Reset
3A Relay
Remote
DIN Rail
LV E5LZ 0016 0149 A
2, 6
146D-2K2D-1100
230 VAC
K t/c
60 to 300°F
High Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV E6KU 0060 0300 A
6, 8
146D-2K2D-1100
230 VAC
K t/c
16 to 149°C
High Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV E6LU 0016 0149 A
6, 8
146D-2K2D-1200
230 VAC
K t/c
60 to 300°F
High Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV E5KU 0060 0300 A
2, 6, 8
146D-2K2D-1200
230 VAC
K t/c
16 to 149°C
High Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV E5LU 0016 0149 A
2, 6, 8
146D-2K2D-2100
230 VAC
K t/c
60 to 300°F
Low Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV E6KY 0060 0300 A
6, 8
146D-2K2D-2100
230 VAC
K t/c
16 to 149°C
Low Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV E6LY 0016 0149 A
6, 8
146D-2K2D-2200
230 VAC
K t/c
60 to 300°F
Low Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV E5KY 0060 0300 A
2, 6, 8
146D-2K2D-2200
230 VAC
K t/c
16 to 149°C
Low Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV E5LY 0016 0149 A
2, 6, 8