Series 146
Series 146
Line
Voltage
Input
Temp Range
Control
Mode
Action
Output
Set Point
Mounting
Retrofit control
See Notes
Below
146D-3J2C-4100
24 VAC
J t/c
0 to 750°C
Low Limit
Auto Reset
3A Relay
Integral
DIN Rail
LV G6JZ 0000 0750 A
6
146D-3J2C-4200
24 VAC
J t/c
0 to 750°C
Low Limit
Auto Reset
3A Relay
Remote
DIN Rail
LV G5JZ 0000 0750 A
2, 6
146D-3J2D-1100
24 VAC
J t/c
32 to 1382°F
High Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV G6HU 0032 1382 A
6, 8
146D-3J2D-1100
24 VAC
J t/c
0 to 750°C
High Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV G6JU 0000 0750 A
6, 8
146D-3J2D-1200
24 VAC
J t/c
32 to 1382°F
High Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV G5HU 0032 1382 A
2, 6, 8
146D-3J2D-1200
24 VAC
J t/c
0 to 750°C
High Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV G5JU 0000 0750 A
2, 6, 8
146D-3J2D-2100
24 VAC
J t/c
32 to 1382°F
Low Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV G6HY 0032 1382 A
6, 8
146D-3J2D-2100
24 VAC
J t/c
0 to 750°C
Low Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV G6JY 0000 0750 A
6, 8
146D-3J2D-2200
24 VAC
J t/c
32 to 1382°F
Low Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV G5HY 0032 1382 A
2, 6, 8
146D-3J2D-2200
24 VAC
J t/c
0 to 750°C
Low Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV G5JY 0000 0750 A
2, 6, 8
146D-3J2D-3100
24 VAC
J t/c
32 to 1382°F
High Limit
Auto Reset
3A Relay
Integral
DIN Rail
LV G6HW 0032 1382 A
6, 8
146D-3J2D-3100
24 VAC
J t/c
0 to 750°C
High Limit
Auto Reset
3A Relay
Integral
DIN Rail
LV G6JW 0000 0750 A
6, 8
146D-3J2D-3200
24 VAC
J t/c
32 to 1382°F
High Limit
Auto Reset
3A Relay
Remote
DIN Rail
LV G5HW 0032 1382 A
2, 6, 8
146D-3J2D-3200
24 VAC
J t/c
0 to 750°C
High Limit
Auto Reset
3A Relay
Remote
DIN Rail
LV G5JW 0000 0750 A
2, 6, 8
146D-3J2D-4100
24 VAC
J t/c
32 to 1382°F
Low Limit
Auto Reset
3A Relay
Integral
DIN Rail
LV G6HZ 0032 1382 A
6, 8
146D-3J2D-4100
24 VAC
J t/c
0 to 750°C
Low Limit
Auto Reset
3A Relay
Integral
DIN Rail
LV G6JZ 0000 0750 A
6, 8
146D-3J2D-4200
24 VAC
J t/c
32 to 1382°F
Low Limit
Auto Reset
3A Relay
Remote
DIN Rail
LV G5HZ 0032 1382 A
2, 6, 8
146D-3J2D-4200
24 VAC
J t/c
0 to 750°C
Low Limit
Auto Reset
3A Relay
Remote
DIN Rail
LV G5JZ 0000 0750 A
2, 6, 8
146D-3J2F-1100
24 VAC
J t/c
32 to 1382°F
High Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV G6HU 0032 1382 A
6
146D-3J2F-1200
24 VAC
J t/c
32 to 1382°F
High Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV G5HU 0032 1382 A
2, 6
146D-3J2F-2100
24 VAC
J t/c
32 to 1382°F
Low Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV G6HY 0032 1382 A
6
146D-3J2F-2200
24 VAC
J t/c
32 to 1382°F
Low Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV G5HY 0032 1382 A
2, 6
146D-3J2F-3100
24 VAC
J t/c
32 to 1382°F
High Limit
Auto Reset
3A Relay
Integral
DIN Rail
LV G6HW 0032 1382 A
6
146D-3J2F-3200
24 VAC
J t/c
32 to 1382°F
High Limit
Auto Reset
3A Relay
Remote
DIN Rail
LV G5HW 0032 1382 A
2, 6
146D-3J2F-4100
24 VAC
J t/c
32 to 1382°F
Low Limit
Auto Reset
3A Relay
Integral
DIN Rail
LV G6HZ 0032 1382 A
6
146D-3J2F-4200
24 VAC
J t/c
32 to 1382°F
Low Limit
Auto Reset
3A Relay
Remote
DIN Rail
LV G5HZ 0032 1382 A
2, 6
146D-3J3C-1100
24 VAC
J t/c
149 to 427°C
High Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV G6JU 0149 0427 A
6
146D-3J3C-1200
24 VAC
J t/c
149 to 427°C
High Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV G5JU 0149 0427 A
2, 6
146D-3J3C-2100
24 VAC
J t/c
149 to 427°C
Low Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV G6JY 0149 0427 A
6
146D-3J3C-2200
24 VAC
J t/c
149 to 427°C
Low Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV G5JY 0149 0427 A
2, 6
146D-3J3C-3100
24 VAC
J t/c
149 to 427°C
High Limit
Auto Reset
3A Relay
Integral
DIN Rail
LV G6JW 0149 0427 A
6
146D-3J3C-3200
24 VAC
J t/c
149 to 427°C
High Limit
Auto Reset
3A Relay
Remote
DIN Rail
LV G5JW 0149 0427 A
2, 6
146D-3J3C-4100
24 VAC
J t/c
149 to 427°C
Low Limit
Auto Reset
3A Relay
Integral
DIN Rail
LV G6JZ 0149 0427 A
6
146D-3J3C-4200
24 VAC
J t/c
149 to 427°C
Low Limit
Auto Reset
3A Relay
Remote
DIN Rail
LV G5JZ 0149 0427 A
2, 6
146D-3J3D-1100
24 VAC
J t/c
300 to 800°F
High Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV G6HU 0300 0800 A
6, 8
146D-3J3D-1100
24 VAC
J t/c
149 to 427°C
High Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV G6JU 0149 0427 A
6, 8
146D-3J3D-1200
24 VAC
J t/c
300 to 800°F
High Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV G5HU 0300 0800 A
2, 6, 8
146D-3J3D-1200
24 VAC
J t/c
149 to 427°C
High Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV G5JU 0149 0427 A
2, 6, 8
146D-3J3D-2100
24 VAC
J t/c
300 to 800°F
Low Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV G6HY 0300 0800 A
6, 8
146D-3J3D-2100
24 VAC
J t/c
149 to 427°C
Low Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV G6JY 0149 0427 A
6, 8
146D-3J3D-2200
24 VAC
J t/c
300 to 800°F
Low Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV G5HY 0300 0800 A
2, 6, 8
Watlow Controls
3/30/2005
Page 23