Series 146 – Watlow Series 146 Retrofit User Manual
Page 24
Series 146
Series 146
Line
Voltage
Input
Temp Range
Control
Mode
Action
Output
Set Point
Mounting
Retrofit control
See Notes
Below
146D-2K5C-2100
230 VAC
K t/c
-17 to 315°C
Low Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV E6LY -017 0315 A
6
146D-2K5C-2200
230 VAC
K t/c
-17 to 315°C
Low Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV E5LY -017 0315 A
2, 6
146D-2K5C-3100
230 VAC
K t/c
-17 to 315°C
High Limit
Auto Reset
3A Relay
Integral
DIN Rail
LV E6LW -017 0315 A
6
146D-2K5C-3200
230 VAC
K t/c
-17 to 315°C
High Limit
Auto Reset
3A Relay
Remote
DIN Rail
LV E5LW -017 0315 A
2, 6
146D-2K5C-4100
230 VAC
K t/c
-17 to 315°C
Low Limit
Auto Reset
3A Relay
Integral
DIN Rail
LV E6LZ -017 0315 A
6
146D-2K5C-4200
230 VAC
K t/c
-17 to 315°C
Low Limit
Auto Reset
3A Relay
Remote
DIN Rail
LV E5LZ -017 0315 A
2, 6
146D-2K5D-1100
230 VAC
K t/c
0 to 600°F
High Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV E6KU 0000 0600 A
6, 8
146D-2K5D-1100
230 VAC
K t/c
-17 to 315°C
High Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV E6LU -017 0315 A
6, 8
146D-2K5D-1200
230 VAC
K t/c
0 to 600°F
High Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV E5KU 0000 0600 A
2, 6, 8
146D-2K5D-1200
230 VAC
K t/c
-17 to 315°C
High Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV E5LU -017 0315 A
2, 6, 8
146D-2K5D-2100
230 VAC
K t/c
0 to 600°F
Low Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV E6KY 0000 0600 A
6, 8
146D-2K5D-2100
230 VAC
K t/c
-17 to 315°C
Low Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV E6LY -017 0315 A
6, 8
146D-2K5D-2200
230 VAC
K t/c
0 to 600°F
Low Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV E5KY 0000 0600 A
2, 6, 8
146D-2K5D-2200
230 VAC
K t/c
-17 to 315°C
Low Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV E5LY -017 0315 A
2, 6, 8
146D-2K5D-3100
230 VAC
K t/c
0 to 600°F
High Limit
Auto Reset
3A Relay
Integral
DIN Rail
LV E6KW 0000 0600 A
6, 8
146D-2K5D-3100
230 VAC
K t/c
-17 to 315°C
High Limit
Auto Reset
3A Relay
Integral
DIN Rail
LV E6LW -017 0315 A
6, 8
146D-2K5D-3200
230 VAC
K t/c
0 to 600°F
High Limit
Auto Reset
3A Relay
Remote
DIN Rail
LV E5KW 0000 0600 A
2, 6, 8
146D-2K5D-3200
230 VAC
K t/c
-17 to 315°C
High Limit
Auto Reset
3A Relay
Remote
DIN Rail
LV E5LW -017 0315 A
2, 6, 8
146D-2K5D-4100
230 VAC
K t/c
0 to 600°F
Low Limit
Auto Reset
3A Relay
Integral
DIN Rail
LV E6KZ 0000 0600 A
6, 8
146D-2K5D-4100
230 VAC
K t/c
-17 to 315°C
Low Limit
Auto Reset
3A Relay
Integral
DIN Rail
LV E6LZ -017 0315 A
6, 8
146D-2K5D-4200
230 VAC
K t/c
0 to 600°F
Low Limit
Auto Reset
3A Relay
Remote
DIN Rail
LV E5KZ 0000 0600 A
2, 6, 8
146D-2K5D-4200
230 VAC
K t/c
-17 to 315°C
Low Limit
Auto Reset
3A Relay
Remote
DIN Rail
LV E5LZ -017 0315 A
2, 6, 8
146D-2K5F-1100
230 VAC
K t/c
0 to 600°F
High Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV E6KU 0000 0600 A
6
146D-2K5F-1200
230 VAC
K t/c
0 to 600°F
High Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV E5KU 0000 0600 A
2, 6
146D-2K5F-2100
230 VAC
K t/c
0 to 600°F
Low Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV E6KY 0000 0600 A
6
146D-2K5F-2200
230 VAC
K t/c
0 to 600°F
Low Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV E5KY 0000 0600 A
2, 6
146D-2K5F-3100
230 VAC
K t/c
0 to 600°F
High Limit
Auto Reset
3A Relay
Integral
DIN Rail
LV E6KW 0000 0600 A
6
146D-2K5F-3200
230 VAC
K t/c
0 to 600°F
High Limit
Auto Reset
3A Relay
Remote
DIN Rail
LV E5KW 0000 0600 A
2, 6
146D-2K5F-4100
230 VAC
K t/c
0 to 600°F
Low Limit
Auto Reset
3A Relay
Integral
DIN Rail
LV E6KZ 0000 0600 A
6
146D-2K5F-4200
230 VAC
K t/c
0 to 600°F
Low Limit
Auto Reset
3A Relay
Remote
DIN Rail
LV E5KZ 0000 0600 A
2, 6
146D-2P1C-1100
230 VAC
100 ohm DIN
-73 to 600°C
High Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV E6RU -073 0600 A
6
146D-2P1C-1200
230 VAC
100 ohm DIN
-73 to 600°C
High Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV E5RU -073 0600 A
2, 6
146D-2P1C-2100
230 VAC
100 ohm DIN
-73 to 600°C
Low Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV E6RY -073 0600 A
6
146D-2P1C-2200
230 VAC
100 ohm DIN
-73 to 600°C
Low Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV E5RY -073 0600 A
2, 6
146D-2P1C-3100
230 VAC
100 ohm DIN
-73 to 600°C
High Limit
Auto Reset
3A Relay
Integral
DIN Rail
LV E6RW -073 0600 A
6
146D-2P1C-3200
230 VAC
100 ohm DIN
-73 to 600°C
High Limit
Auto Reset
3A Relay
Remote
DIN Rail
LV E5RW -073 0600 A
2, 6
146D-2P1C-4100
230 VAC
100 ohm DIN
-73 to 600°C
Low Limit
Auto Reset
3A Relay
Integral
DIN Rail
LV E6RZ -073 0600 A
6
146D-2P1C-4200
230 VAC
100 ohm DIN
-73 to 600°C
Low Limit
Auto Reset
3A Relay
Remote
DIN Rail
LV E5RZ -073 0600 A
2, 6
146D-2P1D-1100
230 VAC
100 ohm DIN
-73 to 600°C
High Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV E6RU -073 0600 A
6, 8
146D-2P1D-1100
230 VAC
100 ohm DIN
-100 to 1112 °F
High Limit
Manual Reset
3A Relay
Integral
DIN Rail
LV E6PU -100 1112 A
6, 8
146D-2P1D-1200
230 VAC
100 ohm DIN
-73 to 600°C
High Limit
Manual Reset
3A Relay
Remote
DIN Rail
LV E5RU -073 0600 A
2, 6, 8
Watlow Controls
3/30/2005
Page 19