Series 146

Series 146

Line

Voltage

Input

Temp Range

Control

Mode

Action

Output

Set Point

Mounting

Retrofit control

See Notes

Below

146E-2626-4N00

230 VAC

K t/c

16 to 149°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5LZ 0016 0149 A

2, 6, 8

146E-2626-4P00

230 VAC

K t/c

60 to 300°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5KZ 0060 0300 A

2, 6, 8

146E-2626-4P00

230 VAC

K t/c

16 to 149°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5LZ 0016 0149 A

2, 6, 8

146E-2626-4S00

230 VAC

K t/c

60 to 300°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5KZ 0060 0300 A

2, 6, 8

146E-2626-4S00

230 VAC

K t/c

16 to 149°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5LZ 0016 0149 A

2, 6, 8

146E-2627-1000

230 VAC

K t/c

32 to 150°F

High Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV E6KU 0032 0150 A

6, 8

146E-2627-1000

230 VAC

K t/c

0 to 66°C

High Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV E6LU 0000 0066 A

6, 8

146E-2627-1N00

230 VAC

K t/c

32 to 150°F

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5KU 0032 0150 A

2, 6, 8

146E-2627-1N00

230 VAC

K t/c

0 to 66°C

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5LU 0000 0066 A

2, 6, 8

146E-2627-1P00

230 VAC

K t/c

32 to 150°F

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5KU 0032 0150 A

2, 6, 8

146E-2627-1P00

230 VAC

K t/c

0 to 66°C

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5LU 0000 0066 A

2, 6, 8

146E-2627-1S00

230 VAC

K t/c

32 to 150°F

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5KU 0032 0150 A

2, 6, 8

146E-2627-1S00

230 VAC

K t/c

0 to 66°C

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5LU 0000 0066 A

2, 6, 8

146E-2627-2000

230 VAC

K t/c

32 to 150°F

Low Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV E6KY 0032 0150 A

6, 8

146E-2627-2000

230 VAC

K t/c

0 to 66°C

Low Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV E6LY 0000 0066 A

6, 8

146E-2627-2N00

230 VAC

K t/c

32 to 150°F

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5KY 0032 0150 A

2, 6, 8

146E-2627-2N00

230 VAC

K t/c

0 to 66°C

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5LY 0000 0066 A

2, 6, 8

146E-2627-2P00

230 VAC

K t/c

32 to 150°F

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5KY 0032 0150 A

2, 6, 8

146E-2627-2P00

230 VAC

K t/c

0 to 66°C

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5LY 0000 0066 A

2, 6, 8

146E-2627-2S00

230 VAC

K t/c

32 to 150°F

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5KY 0032 0150 A

2, 6, 8

146E-2627-2S00

230 VAC

K t/c

0 to 66°C

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5LY 0000 0066 A

2, 6, 8

146E-2627-3000

230 VAC

K t/c

32 to 150°F

High Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV E6KW 0032 0150 A

6, 8

146E-2627-3000

230 VAC

K t/c

0 to 66°C

High Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV E6LW 0000 0066 A

6, 8

146E-2627-3N00

230 VAC

K t/c

32 to 150°F

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5KW 0032 0150 A

2, 6, 8

146E-2627-3N00

230 VAC

K t/c

0 to 66°C

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5LW 0000 0066 A

2, 6, 8

146E-2627-3P00

230 VAC

K t/c

32 to 150°F

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5KW 0032 0150 A

2, 6, 8

146E-2627-3P00

230 VAC

K t/c

0 to 66°C

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5LW 0000 0066 A

2, 6, 8

146E-2627-3S00

230 VAC

K t/c

32 to 150°F

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5KW 0032 0150 A

2, 6, 8

146E-2627-3S00

230 VAC

K t/c

0 to 66°C

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5LW 0000 0066 A

2, 6, 8

146E-2627-4000

230 VAC

K t/c

32 to 150°F

Low Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV E6KZ 0032 0150 A

6, 8

146E-2627-4000

230 VAC

K t/c

0 to 66°C

Low Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV E6LZ 0000 0066 A

6, 8

146E-2627-4N00

230 VAC

K t/c

32 to 150°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5KZ 0032 0150 A

2, 6, 8

146E-2627-4N00

230 VAC

K t/c

0 to 66°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5LZ 0000 0066 A

2, 6, 8

146E-2627-4P00

230 VAC

K t/c

32 to 150°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5KZ 0032 0150 A

2, 6, 8

146E-2627-4P00

230 VAC

K t/c

0 to 66°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5LZ 0000 0066 A

2, 6, 8

146E-2627-4S00

230 VAC

K t/c

32 to 150°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5KZ 0032 0150 A

2, 6, 8

146E-2627-4S00

230 VAC

K t/c

0 to 66°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5LZ 0000 0066 A

2, 6, 8

146E-2628-1000

230 VAC

K t/c

0 to 600°F

High Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV E6KU 0000 0600 A

6, 8

146E-2628-1000

230 VAC

K t/c

-17 to 315°C

High Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV E6LU -017 0315 A

6, 8

146E-2628-1N00

230 VAC

K t/c

0 to 600°F

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5KU 0000 0600 A

2, 6, 8

146E-2628-1N00

230 VAC

K t/c

-17 to 315°C

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5LU -017 0315 A

2, 6, 8