Series 146

Line

Voltage

Input

Temp Range

Control

Mode

Action

Output

Set Point

Mounting

Retrofit control

See Notes

Below

146D-3K2D-1200

24 VAC

K t/c

60 to 300°F

High Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV G5KU 0060 0300 A

2, 6, 8

146D-3K2D-1200

24 VAC

K t/c

16 to 149°C

High Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV G5LU 0016 0149 A

2, 6, 8

146D-3K2D-2100

24 VAC

K t/c

60 to 300°F

Low Limit

Manual Reset

3A Relay

Integral

DIN Rail

LV G6KY 0060 0300 A

6, 8

146D-3K2D-2100

24 VAC

K t/c

16 to 149°C

Low Limit

Manual Reset

3A Relay

Integral

DIN Rail

LV G6LY 0016 0149 A

6, 8

146D-3K2D-2200

24 VAC

K t/c

60 to 300°F

Low Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV G5KY 0060 0300 A

2, 6, 8

146D-3K2D-2200

24 VAC

K t/c

16 to 149°C

Low Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV G5LY 0016 0149 A

2, 6, 8

146D-3K2D-3100

24 VAC

K t/c

60 to 300°F

High Limit

Auto Reset

3A Relay

Integral

DIN Rail

LV G6KW 0060 0300 A

6, 8

146D-3K2D-3100

24 VAC

K t/c

16 to 149°C

High Limit

Auto Reset

3A Relay

Integral

DIN Rail

LV G6LW 0016 0149 A

6, 8

146D-3K2D-3200

24 VAC

K t/c

60 to 300°F

High Limit

Auto Reset

3A Relay

Remote

DIN Rail

LV G5KW 0060 0300 A

2, 6, 8

146D-3K2D-3200

24 VAC

K t/c

16 to 149°C

High Limit

Auto Reset

3A Relay

Remote

DIN Rail

LV G5LW 0016 0149 A

2, 6, 8

146D-3K2D-4100

24 VAC

K t/c

60 to 300°F

Low Limit

Auto Reset

3A Relay

Integral

DIN Rail

LV G6KZ 0060 0300 A

6, 8

146D-3K2D-4100

24 VAC

K t/c

16 to 149°C

Low Limit

Auto Reset

3A Relay

Integral

DIN Rail

LV G6LZ 0016 0149 A

6, 8

146D-3K2D-4200

24 VAC

K t/c

60 to 300°F

Low Limit

Auto Reset

3A Relay

Remote

DIN Rail

LV G5KZ 0060 0300 A

2, 6, 8

146D-3K2D-4200

24 VAC

K t/c

16 to 149°C

Low Limit

Auto Reset

3A Relay

Remote

DIN Rail

LV G5LZ 0016 0149 A

2, 6, 8

146D-3K2F-1100

24 VAC

K t/c

60 to 300°F

High Limit

Manual Reset

3A Relay

Integral

DIN Rail

LV G6KU 0060 0300 A

6

146D-3K2F-1200

24 VAC

K t/c

60 to 300°F

High Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV G5KU 0060 0300 A

2, 6

146D-3K2F-2100

24 VAC

K t/c

60 to 300°F

Low Limit

Manual Reset

3A Relay

Integral

DIN Rail

LV G6KY 0060 0300 A

6

146D-3K2F-2200

24 VAC

K t/c

60 to 300°F

Low Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV G5KY 0060 0300 A

2, 6

146D-3K2F-3100

24 VAC

K t/c

60 to 300°F

High Limit

Auto Reset

3A Relay

Integral

DIN Rail

LV G6KW 0060 0300 A

6

146D-3K2F-3200

24 VAC

K t/c

60 to 300°F

High Limit

Auto Reset

3A Relay

Remote

DIN Rail

LV G5KW 0060 0300 A

2, 6

146D-3K2F-4100

24 VAC

K t/c

60 to 300°F

Low Limit

Auto Reset

3A Relay

Integral

DIN Rail

LV G6KZ 0060 0300 A

6

146D-3K2F-4200

24 VAC

K t/c

60 to 300°F

Low Limit

Auto Reset

3A Relay

Remote

DIN Rail

LV G5KZ 0060 0300 A

2, 6

146D-3K3C-1100

24 VAC

K t/c

0 to 600°C

High Limit

Manual Reset

3A Relay

Integral

DIN Rail

LV G6LU 0000 0600 A

6

146D-3K3C-1200

24 VAC

K t/c

0 to 600°C

High Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV G5LU 0000 0600 A

2, 6

146D-3K3C-2100

24 VAC

K t/c

0 to 600°C

Low Limit

Manual Reset

3A Relay

Integral

DIN Rail

LV G6LY 0000 0600 A

6

146D-3K3C-2200

24 VAC

K t/c

0 to 600°C

Low Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV G5LY 0000 0600 A

2, 6

146D-3K3C-3100

24 VAC

K t/c

0 to 600°C

High Limit

Auto Reset

3A Relay

Integral

DIN Rail

LV G6LW 0000 0600 A

6

146D-3K3C-3200

24 VAC

K t/c

0 to 600°C

High Limit

Auto Reset

3A Relay

Remote

DIN Rail

LV G5LW 0000 0600 A

2, 6

146D-3K3C-4100

24 VAC

K t/c

0 to 600°C

Low Limit

Auto Reset

3A Relay

Integral

DIN Rail

LV G6LZ 0000 0600 A

6

146D-3K3C-4200

24 VAC

K t/c

0 to 600°C

Low Limit

Auto Reset

3A Relay

Remote

DIN Rail

LV G5LZ 0000 0600 A

2, 6

146D-3K3D-1100

24 VAC

K t/c

32 to 1112°F

High Limit

Manual Reset

3A Relay

Integral

DIN Rail

LV G6KU 0032 1112 A

6, 8

146D-3K3D-1100

24 VAC

K t/c

0 to 600°C

High Limit

Manual Reset

3A Relay

Integral

DIN Rail

LV G6LU 0000 0600 A

6, 8

146D-3K3D-1200

24 VAC

K t/c

32 to 1112°F

High Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV G5KU 0032 1112 A

2, 6, 8

146D-3K3D-1200

24 VAC

K t/c

0 to 600°C

High Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV G5LU 0000 0600 A

2, 6, 8

146D-3K3D-2100

24 VAC

K t/c

32 to 1112°F

Low Limit

Manual Reset

3A Relay

Integral

DIN Rail

LV G6KY 0032 1112 A

6, 8

146D-3K3D-2100

24 VAC

K t/c

0 to 600°C

Low Limit

Manual Reset

3A Relay

Integral

DIN Rail

LV G6LY 0000 0600 A

6, 8

146D-3K3D-2200

24 VAC

K t/c

32 to 1112°F

Low Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV G5KY 0032 1112 A

2, 6, 8

146D-3K3D-2200

24 VAC

K t/c

0 to 600°C

Low Limit

Manual Reset

3A Relay

Remote

DIN Rail

LV G5LY 0000 0600 A

2, 6, 8

146D-3K3D-3100

24 VAC

K t/c

32 to 1112°F

High Limit

Auto Reset

3A Relay

Integral

DIN Rail

LV G6KW 0032 1112 A

6, 8

146D-3K3D-3100

24 VAC

K t/c

0 to 600°C

High Limit

Auto Reset

3A Relay

Integral

DIN Rail

LV G6LW 0000 0600 A

6, 8

146D-3K3D-3200

24 VAC

K t/c

32 to 1112°F

High Limit

Auto Reset

3A Relay

Remote

DIN Rail

LV G5KW 0032 1112 A

2, 6, 8