Series 146 – Watlow Series 146 Retrofit User Manual
Page 42

Series 146
Series 146
Line
Voltage
Input
Temp Range
Control
Mode
Action
Output
Set Point
Mounting
Retrofit control
See Notes
Below
146E-1603-2P00
120 VAC
K t/c
32 to 2282°F
Low Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV C5KY 0032 2282 A
2, 6, 8
146E-1603-2P00
120 VAC
K t/c
0 to 1250°C
Low Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV C5LY 0000 1250 A
2, 6, 8
146E-1603-2S00
120 VAC
K t/c
32 to 2282°F
Low Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV C5KY 0032 2282 A
2, 6, 8
146E-1603-2S00
120 VAC
K t/c
0 to 1250°C
Low Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV C5LY 0000 1250 A
2, 6, 8
146E-1603-3000
120 VAC
K t/c
32 to 2282°F
High Limit
Auto Reset
8A Relay
Integral
DIN Rail
LV C6KW 0032 2282 A
6, 8
146E-1603-3000
120 VAC
K t/c
0 to 1250°C
High Limit
Auto Reset
8A Relay
Integral
DIN Rail
LV C6LW 0000 1250 A
6, 8
146E-1603-3N00
120 VAC
K t/c
32 to 2282°F
High Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV C5KW 0032 2282 A
2, 6, 8
146E-1603-3N00
120 VAC
K t/c
0 to 1250°C
High Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV C5LW 0000 1250 A
2, 6, 8
146E-1603-3P00
120 VAC
K t/c
32 to 2282°F
High Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV C5KW 0032 2282 A
2, 6, 8
146E-1603-3P00
120 VAC
K t/c
0 to 1250°C
High Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV C5LW 0000 1250 A
2, 6, 8
146E-1603-3S00
120 VAC
K t/c
32 to 2282°F
High Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV C5KW 0032 2282 A
2, 6, 8
146E-1603-3S00
120 VAC
K t/c
0 to 1250°C
High Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV C5LW 0000 1250 A
2, 6, 8
146E-1603-4000
120 VAC
K t/c
32 to 2282°F
Low Limit
Auto Reset
8A Relay
Integral
DIN Rail
LV C6KZ 0032 2282 A
6, 8
146E-1603-4000
120 VAC
K t/c
0 to 1250°C
Low Limit
Auto Reset
8A Relay
Integral
DIN Rail
LV C6LZ 0000 1250 A
6, 8
146E-1603-4N00
120 VAC
K t/c
32 to 2282°F
Low Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV C5KZ 0032 2282 A
2, 6, 8
146E-1603-4N00
120 VAC
K t/c
0 to 1250°C
Low Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV C5LZ 0000 1250 A
2, 6, 8
146E-1603-4P00
120 VAC
K t/c
32 to 2282°F
Low Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV C5KZ 0032 2282 A
2, 6, 8
146E-1603-4P00
120 VAC
K t/c
0 to 1250°C
Low Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV C5LZ 0000 1250 A
2, 6, 8
146E-1603-4S00
120 VAC
K t/c
32 to 2282°F
Low Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV C5KZ 0032 2282 A
2, 6, 8
146E-1603-4S00
120 VAC
K t/c
0 to 1250°C
Low Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV C5LZ 0000 1250 A
2, 6, 8
146E-1611-1000
120 VAC
K t/c
32 to 1112°F
High Limit
Manual Reset
8A Relay
Integral
DIN Rail
LV C6KU 0032 1112 A
6, 8
146E-1611-1000
120 VAC
K t/c
0 to 600°C
High Limit
Manual Reset
8A Relay
Integral
DIN Rail
LV C6LU 0000 0600 A
6, 8
146E-1611-1N00
120 VAC
K t/c
32 to 1112°F
High Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV C5KU 0032 1112 A
2, 6, 8
146E-1611-1N00
120 VAC
K t/c
0 to 600°C
High Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV C5LU 0000 0600 A
2, 6, 8
146E-1611-1P00
120 VAC
K t/c
32 to 1112°F
High Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV C5KU 0032 1112 A
2, 6, 8
146E-1611-1P00
120 VAC
K t/c
0 to 600°C
High Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV C5LU 0000 0600 A
2, 6, 8
146E-1611-1S00
120 VAC
K t/c
32 to 1112°F
High Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV C5KU 0032 1112 A
2, 6, 8
146E-1611-1S00
120 VAC
K t/c
0 to 600°C
High Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV C5LU 0000 0600 A
2, 6, 8
146E-1611-2000
120 VAC
K t/c
32 to 1112°F
Low Limit
Manual Reset
8A Relay
Integral
DIN Rail
LV C6KY 0032 1112 A
6, 8
146E-1611-2000
120 VAC
K t/c
0 to 600°C
Low Limit
Manual Reset
8A Relay
Integral
DIN Rail
LV C6LY 0000 0600 A
6, 8
146E-1611-2N00
120 VAC
K t/c
32 to 1112°F
Low Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV C5KY 0032 1112 A
2, 6, 8
146E-1611-2N00
120 VAC
K t/c
0 to 600°C
Low Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV C5LY 0000 0600 A
2, 6, 8
146E-1611-2P00
120 VAC
K t/c
32 to 1112°F
Low Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV C5KY 0032 1112 A
2, 6, 8
146E-1611-2P00
120 VAC
K t/c
0 to 600°C
Low Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV C5LY 0000 0600 A
2, 6, 8
146E-1611-2S00
120 VAC
K t/c
32 to 1112°F
Low Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV C5KY 0032 1112 A
2, 6, 8
146E-1611-2S00
120 VAC
K t/c
0 to 600°C
Low Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV C5LY 0000 0600 A
2, 6, 8
146E-1611-3000
120 VAC
K t/c
32 to 1112°F
High Limit
Auto Reset
8A Relay
Integral
DIN Rail
LV C6KW 0032 1112 A
6, 8
146E-1611-3000
120 VAC
K t/c
0 to 600°C
High Limit
Auto Reset
8A Relay
Integral
DIN Rail
LV C6LW 0000 0600 A
6, 8
146E-1611-3N00
120 VAC
K t/c
32 to 1112°F
High Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV C5KW 0032 1112 A
2, 6, 8
146E-1611-3N00
120 VAC
K t/c
0 to 600°C
High Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV C5LW 0000 0600 A
2, 6, 8
146E-1611-3P00
120 VAC
K t/c
32 to 1112°F
High Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV C5KW 0032 1112 A
2, 6, 8
Watlow Controls
3/30/2005
Page 37