Series 146 – Watlow Series 146 Retrofit User Manual
Page 41
Series 146
Series 146
Line
Voltage
Input
Temp Range
Control
Mode
Action
Output
Set Point
Mounting
Retrofit control
See Notes
Below
146E-1602-1N00
120 VAC
J t/c
0 to 750°C
High Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV C5JU 0000 0750 A
2, 6, 8
146E-1602-1P00
120 VAC
J t/c
32 to 1382°F
High Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV C5HU 0032 1382 A
2, 6, 8
146E-1602-1P00
120 VAC
J t/c
0 to 750°C
High Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV C5JU 0000 0750 A
2, 6, 8
146E-1602-1S00
120 VAC
J t/c
32 to 1382°F
High Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV C5HU 0032 1382 A
2, 6, 8
146E-1602-1S00
120 VAC
J t/c
0 to 750°C
High Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV C5JU 0000 0750 A
2, 6, 8
146E-1602-2000
120 VAC
J t/c
32 to 1382°F
Low Limit
Manual Reset
8A Relay
Integral
DIN Rail
LV C6HY 0032 1382 A
6, 8
146E-1602-2000
120 VAC
J t/c
0 to 750°C
Low Limit
Manual Reset
8A Relay
Integral
DIN Rail
LV C6JY 0000 0750 A
6, 8
146E-1602-2N00
120 VAC
J t/c
32 to 1382°F
Low Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV C5HY 0032 1382 A
2, 6, 8
146E-1602-2N00
120 VAC
J t/c
0 to 750°C
Low Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV C5JY 0000 0750 A
2, 6, 8
146E-1602-2P00
120 VAC
J t/c
32 to 1382°F
Low Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV C5HY 0032 1382 A
2, 6, 8
146E-1602-2P00
120 VAC
J t/c
0 to 750°C
Low Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV C5JY 0000 0750 A
2, 6, 8
146E-1602-2S00
120 VAC
J t/c
32 to 1382°F
Low Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV C5HY 0032 1382 A
2, 6, 8
146E-1602-2S00
120 VAC
J t/c
0 to 750°C
Low Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV C5JY 0000 0750 A
2, 6, 8
146E-1602-3000
120 VAC
J t/c
32 to 1382°F
High Limit
Auto Reset
8A Relay
Integral
DIN Rail
LV C6HW 0032 1382 A
6, 8
146E-1602-3000
120 VAC
J t/c
0 to 750°C
High Limit
Auto Reset
8A Relay
Integral
DIN Rail
LV C6JW 0000 0750 A
6, 8
146E-1602-3N00
120 VAC
J t/c
32 to 1382°F
High Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV C5HW 0032 1382 A
2, 6, 8
146E-1602-3N00
120 VAC
J t/c
0 to 750°C
High Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV C5JW 0000 0750 A
2, 6, 8
146E-1602-3P00
120 VAC
J t/c
32 to 1382°F
High Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV C5HW 0032 1382 A
2, 6, 8
146E-1602-3P00
120 VAC
J t/c
0 to 750°C
High Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV C5JW 0000 0750 A
2, 6, 8
146E-1602-3S00
120 VAC
J t/c
32 to 1382°F
High Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV C5HW 0032 1382 A
2, 6, 8
146E-1602-3S00
120 VAC
J t/c
0 to 750°C
High Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV C5JW 0000 0750 A
2, 6, 8
146E-1602-4000
120 VAC
J t/c
32 to 1382°F
Low Limit
Auto Reset
8A Relay
Integral
DIN Rail
LV C6HZ 0032 1382 A
6, 8
146E-1602-4000
120 VAC
J t/c
0 to 750°C
Low Limit
Auto Reset
8A Relay
Integral
DIN Rail
LV C6JZ 0000 0750 A
6, 8
146E-1602-4N00
120 VAC
J t/c
32 to 1382°F
Low Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV C5HZ 0032 1382 A
2, 6, 8
146E-1602-4N00
120 VAC
J t/c
0 to 750°C
Low Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV C5JZ 0000 0750 A
2, 6, 8
146E-1602-4P00
120 VAC
J t/c
32 to 1382°F
Low Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV C5HZ 0032 1382 A
2, 6, 8
146E-1602-4P00
120 VAC
J t/c
0 to 750°C
Low Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV C5JZ 0000 0750 A
2, 6, 8
146E-1602-4S00
120 VAC
J t/c
32 to 1382°F
Low Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV C5HZ 0032 1382 A
2, 6, 8
146E-1602-4S00
120 VAC
J t/c
0 to 750°C
Low Limit
Auto Reset
8A Relay
Remote
DIN Rail
LV C5JZ 0000 0750 A
2, 6, 8
146E-1603-1000
120 VAC
K t/c
32 to 2282°F
High Limit
Manual Reset
8A Relay
Integral
DIN Rail
LV C6KU 0032 2282 A
6, 8
146E-1603-1000
120 VAC
K t/c
0 to 1250°C
High Limit
Manual Reset
8A Relay
Integral
DIN Rail
LV C6LU 0000 1250 A
6, 8
146E-1603-1N00
120 VAC
K t/c
32 to 2282°F
High Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV C5KU 0032 2282 A
2, 6, 8
146E-1603-1N00
120 VAC
K t/c
0 to 1250°C
High Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV C5LU 0000 1250 A
2, 6, 8
146E-1603-1P00
120 VAC
K t/c
32 to 2282°F
High Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV C5KU 0032 2282 A
2, 6, 8
146E-1603-1P00
120 VAC
K t/c
0 to 1250°C
High Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV C5LU 0000 1250 A
2, 6, 8
146E-1603-1S00
120 VAC
K t/c
32 to 2282°F
High Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV C5KU 0032 2282 A
2, 6, 8
146E-1603-1S00
120 VAC
K t/c
0 to 1250°C
High Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV C5LU 0000 1250 A
2, 6, 8
146E-1603-2000
120 VAC
K t/c
32 to 2282°F
Low Limit
Manual Reset
8A Relay
Integral
DIN Rail
LV C6KY 0032 2282 A
6, 8
146E-1603-2000
120 VAC
K t/c
0 to 1250°C
Low Limit
Manual Reset
8A Relay
Integral
DIN Rail
LV C6LY 0000 1250 A
6, 8
146E-1603-2N00
120 VAC
K t/c
32 to 2282°F
Low Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV C5KY 0032 2282 A
2, 6, 8
146E-1603-2N00
120 VAC
K t/c
0 to 1250°C
Low Limit
Manual Reset
8A Relay
Remote
DIN Rail
LV C5LY 0000 1250 A
2, 6, 8
Watlow Controls
3/30/2005
Page 36