beautypg.com

Series 146 – Watlow Series 146 Retrofit User Manual

Page 83

background image

Series 146

Series 146

Line

Voltage

Input

Temp Range

Control

Mode

Action

Output

Set Point

Mounting

Retrofit control

See Notes

Below

146E-2K3D-4100

230 VAC

K t/c

0 to 600°C

Low Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV E6LZ 0000 0600 A

3, 6, 8

146E-2K3D-4200

230 VAC

K t/c

32 to 1112°F

Low Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV E5KZ 0032 1112 A

2, 3, 6, 8

146E-2K3D-4200

230 VAC

K t/c

0 to 600°C

Low Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV E5LZ 0000 0600 A

2, 3, 6, 8

146E-2K3F-1100

230 VAC

K t/c

32 to 1112°F

High Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV E6KU 0032 1112 A

3, 6

146E-2K3F-1200

230 VAC

K t/c

32 to 1112°F

High Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV E5KU 0032 1112 A

2, 3, 6

146E-2K3F-2100

230 VAC

K t/c

32 to 1112°F

Low Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV E6KY 0032 1112 A

3, 6

146E-2K3F-2200

230 VAC

K t/c

32 to 1112°F

Low Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV E5KY 0032 1112 A

2, 3, 6

146E-2K3F-3100

230 VAC

K t/c

32 to 1112°F

High Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV E6KW 0032 1112 A

3, 6

146E-2K3F-3200

230 VAC

K t/c

32 to 1112°F

High Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV E5KW 0032 1112 A

2, 3, 6

146E-2K3F-4100

230 VAC

K t/c

32 to 1112°F

Low Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV E6KZ 0032 1112 A

3, 6

146E-2K3F-4200

230 VAC

K t/c

32 to 1112°F

Low Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV E5KZ 0032 1112 A

2, 3, 6

146E-2K4C-1100

230 VAC

K t/c

0 to 66°C

High Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV E6LU 0000 0066 A

3, 6

146E-2K4C-1200

230 VAC

K t/c

0 to 66°C

High Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV E5LU 0000 0066 A

2, 3, 6

146E-2K4C-2100

230 VAC

K t/c

0 to 66°C

Low Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV E6LY 0000 0066 A

3, 6

146E-2K4C-2200

230 VAC

K t/c

0 to 66°C

Low Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV E5LY 0000 0066 A

2, 3, 6

146E-2K4C-3100

230 VAC

K t/c

0 to 66°C

High Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV E6LW 0000 0066 A

3, 6

146E-2K4C-3200

230 VAC

K t/c

0 to 66°C

High Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV E5LW 0000 0066 A

2, 3, 6

146E-2K4C-4100

230 VAC

K t/c

0 to 66°C

Low Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV E6LZ 0000 0066 A

3, 6

146E-2K4C-4200

230 VAC

K t/c

0 to 66°C

Low Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV E5LZ 0000 0066 A

2, 3, 6

146E-2K4D-1100

230 VAC

K t/c

32 to 150°F

High Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV E6KU 0032 0150 A

3, 6, 8

146E-2K4D-1100

230 VAC

K t/c

0 to 66°C

High Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV E6LU 0000 0066 A

3, 6, 8

146E-2K4D-1200

230 VAC

K t/c

32 to 150°F

High Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV E5KU 0032 0150 A

2, 3, 6, 8

146E-2K4D-1200

230 VAC

K t/c

0 to 66°C

High Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV E5LU 0000 0066 A

2, 3, 6, 8

146E-2K4D-2100

230 VAC

K t/c

32 to 150°F

Low Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV E6KY 0032 0150 A

3, 6, 8

146E-2K4D-2100

230 VAC

K t/c

0 to 66°C

Low Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV E6LY 0000 0066 A

3, 6, 8

146E-2K4D-2200

230 VAC

K t/c

32 to 150°F

Low Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV E5KY 0032 0150 A

2, 3, 6, 8

146E-2K4D-2200

230 VAC

K t/c

0 to 66°C

Low Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV E5LY 0000 0066 A

2, 3, 6, 8

146E-2K4D-3100

230 VAC

K t/c

32 to 150°F

High Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV E6KW 0032 0150 A

3, 6, 8

146E-2K4D-3100

230 VAC

K t/c

0 to 66°C

High Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV E6LW 0000 0066 A

3, 6, 8

146E-2K4D-3200

230 VAC

K t/c

32 to 150°F

High Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV E5KW 0032 0150 A

2, 3, 6, 8

146E-2K4D-3200

230 VAC

K t/c

0 to 66°C

High Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV E5LW 0000 0066 A

2, 3, 6, 8

146E-2K4D-4100

230 VAC

K t/c

32 to 150°F

Low Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV E6KZ 0032 0150 A

3, 6, 8

146E-2K4D-4100

230 VAC

K t/c

0 to 66°C

Low Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV E6LZ 0000 0066 A

3, 6, 8

146E-2K4D-4200

230 VAC

K t/c

32 to 150°F

Low Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV E5KZ 0032 0150 A

2, 3, 6, 8

146E-2K4D-4200

230 VAC

K t/c

0 to 66°C

Low Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV E5LZ 0000 0066 A

2, 3, 6, 8

146E-2K4F-1100

230 VAC

K t/c

32 to 150°F

High Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV E6KU 0032 0150 A

3, 6

146E-2K4F-1200

230 VAC

K t/c

32 to 150°F

High Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV E5KU 0032 0150 A

2, 3, 6

146E-2K4F-2100

230 VAC

K t/c

32 to 150°F

Low Limit

Manual Reset

10A Relay

Integral

DIN Rail

LV E6KY 0032 0150 A

3, 6

146E-2K4F-2200

230 VAC

K t/c

32 to 150°F

Low Limit

Manual Reset

10A Relay

Remote

DIN Rail

LV E5KY 0032 0150 A

2, 3, 6

146E-2K4F-3100

230 VAC

K t/c

32 to 150°F

High Limit

Auto Reset

10A Relay

Integral

DIN Rail

LV E6KW 0032 0150 A

3, 6

146E-2K4F-3200

230 VAC

K t/c

32 to 150°F

High Limit

Auto Reset

10A Relay

Remote

DIN Rail

LV E5KW 0032 0150 A

2, 3, 6