After creating raid groups – ATTO Technology FastStream SC 5700 User Manual
Page 17

12
After creating RAID groups
1
If you are not already in the
ExpressNAV Storage Manager,
type the IP address of your
appliance in a standard browser.
On the splash screen, click
Enter Here. In the box provided,
type in your user name and
password, and click
OK.
2
Click on the
Diagnostics button on the left
hand side of the ExpressNAV Storage
Manager.
3
Choose either I
nitialize and Verify Drives or
Read-Only Drive Test from the Select User
Process menu.
4
Click
Next.
5
If no drives appear in the information box, click
on the
System Scan button.
If drives are available, click on the drives you
wish to verify, initialize or test; the drives are
highlighted.
6
Click
Commit.
CAUTION
CAUTION
Do not restart the FastStream or
disconnect or power cycle drives during
Drive Initialization and Verification or you
must start the verification process from the
beginning.
7
A warning box appears. In the warning box,
verify that you want to complete the
configuration by clicking on
Yes. Clicking on No
ends the procedure without making a change.
8
If you chose to initialize and verify drives, the
Health and Status Monitor page appears and
all data on the previously-highlighted drives has
been erased.
If you chose to do a read-only test, the
Drive
Performance and Health page appears
showing what tests are running and their
results. You may select other tests to run or
continue on to other tasks.