Extron Electronics SSP 7.1 User Guide User Manual
Page 86
X^
— Volume Adjustment (0 - 100, default = 50 dB; corresponding to attenuation of -100
to 0 dB in 1 dB steps).
Max volume (no attenuation) = 0 dB; Min volume (full attenuation) = -100 dB
NOTE: The unit response to a command adjusting the volume always has three digits
and, if necessary, includes leading zeros. The command does not have to include
any leading zeros.
Example
Command: 50V (set the volume to 50 dB; no leading 0)
Response: Vol050] (volume set to 50 dB; with leading 0)
X&
— Furthest speaker distance (in units of 0.01 seconds; default = 0)
NOTE: Furthest speaker distance is included for reference only; it is used only with the
SSP 7.1 Setup and Control Software (see
X(
— Input gain and attenuation readout (0 to +24 dB in 1 dB steps; default 0 dB)
X1)
— Mono source
1 = Left
2 = Right
3 = Left + Right (default)
X1@
— Listening Mode (Matrix Decode Mode indicator on the front panel)
1 = Stereo
2 = Mono
3 = Stereo to All
4 = Mono to All
5 = Dolby Pro Logic
6 = Dolby Pro Logic II/IIx Movie
7 = Dolby Pro Logic II/IIx Music
8 = Dolby Digital 5.1
9 = Dolby Digital EX
10 = Dolby Digital Pro Logic IIx Movie
11 = Dolby Digital Pro Logic IIx Music
12 = DTS or DTS 96/24
13 = DTS ES Matrix or DTS 96/24 ES Matrix
14 = DTS ES Discrete
15 = DTS + Dolby EX or DTS 96/24 + Dolby EX
16 = DTS + Dolby Pro Logic IIx Movie or DTS 96/24 + Dolby Pro Logic IIx Movie
17 = DTS + Dolby Pro Logic IIx Music or DTS 96/24 + Dolby Pro Logic IIx Music
18 = DTS Neo:6 Cinema
19 = DTS Neo:6 Music
X1#
— Status
0 = Not present or malfunction
1 = present or OK
X1$
— Internal temperature in °C
X1%
— Speaker delay (default = 0 on all channels)
SSP 7.1 • SIS Commands