Warner Electric FM Series Foot Mounted Load Cells AC10 Measuring System A-B-C30 User Manual
Page 18

J6 Analog Outputs Terminal
The J6 terminal provides the connections for the
two 10 volt DC outputs. Each output can provide
up to 30 milliamp current.
During setup, each output is individually
scaleable to meet the requirements needed to
calibrate the indicator, drive, or control connect-
ed to the board. The board circuitry is designed
to allow a switch to be connected at Terminal J5.
This switch allows the user to monitor the Output
#2 signal with respect to total tension, or the ten-
sion applied to either Tensioncell.
Terminal
Label
Description
J6-1
Out2
Scaleable -10 to +10 VDC Output
J6-2
Gnd
Common
J6-3
Out1
Scaleable -10 to +10 VDC Output
J64
Gnd
Common
J7 Threshold Relay Terminal
J7 provides the connections for utilizing the
AC10 Threshold Relay which is a form "C" dry
relay contact, rated at 1 Amp. During setup, the
threshold (percentage of total tension) is pro-
grammed to operate when the total tension is
either above or below the threshold value.
Initial Electrical Checks
Before applying power:
Note: Make sure that the Input Power Selector Switch matches the available input voltage.
Verify that the 8-position dip switch is set as follows:
Switch 1
2
3
4
5
6
7
8
Position
ON ON ON ON OFF ON ON ON
Apply power.
The red Run Mode LED in the lower right hand corner of the board should be flashing.
18
Warner Electric • 800-825-9050
P-2012-2
The contact may be wired to function in either
the normally open or normally closed state.
Terminal
Label
Description
J7-1
NC
Normally Closed Contact
J7-2
COM
Common
J7-3
NO
Normally Open Contact
J8 RS232 Output Terminal
J8 provides the cable connections for interfac-
ing the PSAC 10 board with a PC to monitor
total tension and tension applied to each
Tensioncell. Data is transferred in ASCII text for-
mat.
Terminal
Label
Description
J8-1
Gnd
Ground
J8-2
Tx-
Data Line +
J8-3
Tx+
Data Line-
J9 (Spare)
Out 2
Gnd
Out 1
Gnd
J6
Output #2 ( -10 to +10 VDC)
Common
Output #1 ( -10 to + VDC)
Common
1
2
3
4
Normally Closed
Common
Normally Open
J7
NC
COM
NO
1
2
3
Ground
Data Line -
Data Line +
J8
Gnd
Tx-
Tx+
1
2
3