beautypg.com

Vanguard CT-7000 S2 User Manual

Page 35

background image

REV 2 CT-7000 S2 USER’S MANUAL

30

3.1.14. Configuring the Channel Settings

The CT-7000 S2 is available with 3, 6, or 12 contact inputs. Since most common timing
applications require the use of only 3 contact timing channels and one travel transducer
channel, there is no need to print data for more than 3 timing channels and one transducer
channel on the graphic and tabulated reports. The CT-7000 S2 is configured to print 3 contact
channels by default (channels 1, 2, and 3) and one transducer channel (transducer channel #1).
The default settings can be changed using the steps below:

a. Start from the “START-UP” menu:

Press the

[3]

key (SETUP).

b. The following screen will be displayed:

Press the

[4]

key (NEXT PAGE).

c. The following screen will be displayed:

Press the

[2]

key (NUMBER OF CHANNELS).

d. The following screen will be displayed:

NOTE

The number of channels listed on this screen depends on the CT-7000 model.
For example, if your unit has only 3 channels (Model CT-7000 S2-3), only option
1 (3 Contacts) will be available.

Press either the

[1]

key (3 CONTACTS) or the

[2]

key (6 CONTACTS) to select the

corresponding number of contact channels.

NUMBER OF CHANNELS
1. 3 CONTACTS

2. 6 CONTACTS

3. 12 CONTACTS

1. SHOT DESCRIPTION

2. NUMBER OF CHANNELS

3. SET DATE & TIME

4. NEXT PAGE

1. ANALYSIS POINTS

2. MEASUREMENT UNITS

3. SAVE / RESTORE

4. NEXT PAGE

1. TIME BRKR 02/04/11

2. GET RSLT 09:04:05

3. SETUP

4. DIAGNOSTICS