Vanguard CT-7000 S2 User Manual
Page 35
REV 2 CT-7000 S2 USER’S MANUAL
30
3.1.14. Configuring the Channel Settings
The CT-7000 S2 is available with 3, 6, or 12 contact inputs. Since most common timing
applications require the use of only 3 contact timing channels and one travel transducer
channel, there is no need to print data for more than 3 timing channels and one transducer
channel on the graphic and tabulated reports. The CT-7000 S2 is configured to print 3 contact
channels by default (channels 1, 2, and 3) and one transducer channel (transducer channel #1).
The default settings can be changed using the steps below:
a. Start from the “START-UP” menu:
Press the
[3]
key (SETUP).
b. The following screen will be displayed:
Press the
[4]
key (NEXT PAGE).
c. The following screen will be displayed:
Press the
[2]
key (NUMBER OF CHANNELS).
d. The following screen will be displayed:
NOTE
The number of channels listed on this screen depends on the CT-7000 model.
For example, if your unit has only 3 channels (Model CT-7000 S2-3), only option
1 (3 Contacts) will be available.
Press either the
[1]
key (3 CONTACTS) or the
[2]
key (6 CONTACTS) to select the
corresponding number of contact channels.
NUMBER OF CHANNELS
1. 3 CONTACTS
2. 6 CONTACTS
3. 12 CONTACTS
1. SHOT DESCRIPTION
2. NUMBER OF CHANNELS
3. SET DATE & TIME
4. NEXT PAGE
1. ANALYSIS POINTS
2. MEASUREMENT UNITS
3. SAVE / RESTORE
4. NEXT PAGE
1. TIME BRKR 02/04/11
2. GET RSLT 09:04:05
3. SETUP
4. DIAGNOSTICS