Table 8.0 Review Record Procedure (continued)

STEP ACTION

DMOM DISPLAY

8-5

The “number of tests” display also shows the
date and the time. Scroll through the test
record (using the

∧ and ∨ keys to scroll).

When the test record of interest appears,
press the ENTER key to select it.





8-6

Pressing the ENTER key (from step 8-5)
will list all test data, including test number,
test current, burn-in time, and the measured
resistance value.

NOTE

The test record in this example contains 2
tests.



8-7

Press the

∧ key to view to the next test. Press

the

key to return to the previous test.

Press the STOP key to return to the START
MENU
.




This completes the Review Record Procedure.

TEST NUMBER: 1

TEST CURRENT: 100A
BURN - IN TIME: 5 Sec

500.3 MICRO-OHMS

TEST NUMBER: 2

TEST CURRENT: 50A
BURN - IN TIME: 5 Sec

500.1 MICRO-OHMS

2 TESTS

12/11/08 17:27:00