beautypg.com

Vanguard DMOM-100_200 s2 User Manual

Page 11

background image

DMOM-100/200 Series 2 Operating Procedures

11

Rev 2, 2009

2.2 DMOM-200 Series 2 Specifications
DMOM-200 specifications and leading particulars are listed in Table 2.0.

Table 2.0 DMOM-200 Series 2 Specifications

MODEL ...................... DMOM-200 Series 2

TYPE ............................. Special-Purpose Test Equipment, Portable, Low Resistance-Ohmmeter

CONFIGURATION...... Third-generation (improved design, superseding original model)

SIZE (inches) .............. 16.8 Wide by 12.6 High by 10.6 Deep (42.7 Cm x 32 Cm x 30.5 Cm)

WEIGHT........................ 33 pounds (14.97 Kg)

OPERATING ............... 100-240Vac, 8A, 50/60 Hz, with 10A circuit breaker
VOLTAGE

TEST CURRENT
RANGE
......................... 10 Amperes to 200 Amperes, selectable in 1 ampere steps

RESISTANCE
RANGE
......................... 1 micro-ohm to 300 milli-ohms

ACCURACY................. ± 1 % of Reading, ± 1 Count

MEMORY...................... 63 records of 96 readings each

DISPLAY ...................... Backlit LCD, 4-lines high by 20 characters wide

CONTROL.................... Keypad: 10 number keys and 6-function keys

PRINTER ...................... Thermal printer, 2.5-inch wide thermal paper

POWER ........................ 8 amps, 100-240Vac, 50/60 Hz, with built in 10A circuit breaker

UNIT PROTECTION... Thermal-overload sensor and cutoff

INTERFACE................. RS-232C Connector Port for PC Interface

ENVIRONMENT .......... Operating: 0°C to 55°C; Storage: -40°C to 65°C

FURNISHED ITEMS... One power cord, one ground cable, two 30-ft. test lead cables

EXPENDABLES ........ Paper, Thermal sensitive, 2.5-inch wide roll (VIC p/n TP3)

WARRANTY ................ One-Year Parts & Labor (Post-Warranty Service Contracts Available)

DMOM-200 S2 SPECIFICATIONS ARE SUBJECT TO UPGRADES AND MAY BE CHANGED WITHOUT PRIOR NOTICE.