ADSP-TS201S
Link Port—Data In Timing
with
timing for the LVDS link ports.
Table 33. Link Port—Data In Timing
Parameter
Description
Min
Max
Unit
Inputs
t
LCLKIP
LxCLKIN Period (
Greater of 1.8
or 0.9 × t
CCLK
1
12.5
ns
t
LDIS
LxDATI Input Setup (
)
0.20
1,
2
0.25
1,
3
0.30
1,
4
0.35
1,
5
ns
ns
ns
ns
t
LDIH
LxDATI Input Hold (
0.20
1, 2
0.25
1, 3
0.30
1, 4
0.35
1, 5
ns
ns
ns
ns
t
BCMPIS
LxBCMPI Setup (
)
2 × t
LCLKIP
1
ns
t
BCMPIH
LxBCMPI Hold (
2 × t
LCLKIP
1
ns
1
Timing is relative to the 0 differential voltage (V
OD
= 0).
2
|V
ID
| = 250 mV
3
|V
ID
| = 217 mV
4
|V
ID
| = 206 mV
5
|V
ID
| = 195 mV
Figure 24. Link Ports—Last Received Quad Word
LxCLKIN
LxDATI
V
OD
= 0V
V
OD
= 0V
t
BCMPIS
LxBCMPI
t
BCMPIH
FIRST EDGE IN FIFTH SHORT WORD IN A QUAD WORD