beautypg.com

Link port-data in timing, Link port—data in timing, Adsp-ts201s – Analog Devices TigerSHARC ADSP-TS201S User Manual

Page 34

background image

Rev. C

|

Page 34 of 48

|

December 2006

ADSP-TS201S

Link Port—Data In Timing

Table 33

with

Figure 24

and

Figure 25

provide the data in

timing for the LVDS link ports.

Table 33. Link Port—Data In Timing

Parameter

Description

Min

Max

Unit

Inputs

t

LCLKIP

LxCLKIN Period (

Figure 25

)

Greater of 1.8
or 0.9 × t

CCLK

1

12.5

ns

t

LDIS

LxDATI Input Setup (

Figure 25

)

0.20

1,

2

0.25

1,

3

0.30

1,

4

0.35

1,

5

ns
ns
ns
ns

t

LDIH

LxDATI Input Hold (

Figure 25

)

0.20

1, 2

0.25

1, 3

0.30

1, 4

0.35

1, 5

ns
ns
ns
ns

t

BCMPIS

LxBCMPI Setup (

Figure 24

)

2 × t

LCLKIP

1

ns

t

BCMPIH

LxBCMPI Hold (

Figure 24

)

2 × t

LCLKIP

1

ns

1

Timing is relative to the 0 differential voltage (V

OD

= 0).

2

|V

ID

| = 250 mV

3

|V

ID

| = 217 mV

4

|V

ID

| = 206 mV

5

|V

ID

| = 195 mV

Figure 24. Link Ports—Last Received Quad Word

LxCLKIN

LxDATI

V

OD

= 0V

V

OD

= 0V

t

BCMPIS

LxBCMPI

t

BCMPIH

FIRST EDGE IN FIFTH SHORT WORD IN A QUAD WORD