LevelOne IES-1085 User Manual
Page 104
![background image](/manuals/351522/104/background.png)
User Manual
Page 104
4. Example:
The following example sets new power budget 246 Watts to Switch:
switch_a(config)#poe system-power-budget 246
switch_a(config)#
Enable Mode:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode.
fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen.
switch_a(config)#interface fe1
switch_a(config-if )#
2. Usage:
Use poe enable command to enable this port to discover Powered Device (PD) connected
to this port.
Use the no poe enable to disable this function.
3. Command Syntax:
(no) poe enable
4. Example:
The following example shows the use of poe enable to the interface fe1 (port 1):
switch_a(config)#interface fe1
switch_a(config-if )#poe enable
switch_a(config-if )#
Fixed Power Limit (W):
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode.
fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen.
switch_a(config)#interface fe1
switch_a(config-if )#
2. Usage:
Use this command to specify the fixed power limit for this port to provide power to PD.
3. Command Syntax:
poe fixed-power-limit LEVEL
LEVEL <1-15.4> specifies the fixed power limit (Watts) for this port to provide power to PD.